Elatec GmbH
Page 46 of 65
7.6 Miscellaneous Commands
7.6.1
Get Station ID „g‟
Use this command to retrieve the station ID of the reader.
Command:
‘g’
Answer
Description
Data<CR><LF>
Station ID of the reader (1 byte)
7.6.2 Antenna Power O
ff „poff‟
Use this command to turn off the RF-field and save energy. All present tags in the antenna field are
powered down and reset.
Command:
‘poff’
Answer
Description
‘P<CR><LF>’
Power off command performed
7.6.3 Antenna Power O
n „pon‟
Use this command to turn on the RF-field manually. If a tag-related command is submitted, the RF-
field is also turned on.
Command:
‘pon’
Answer
Description
‘P<CR><LF>’
Power on command performed
7.6.4
Get Version „v‟
Use this command to receive the current firmware version of the reader.
Command:
‘v’
Answer
Description
‘MultiISO 1.15<CR><LF>’
Version string
7.6.5
Reset „x‟
Use this command to perform a software reset of the reader.
Command:
‘x’
Answer
Description
‘MultiISO 1.15<CR><LF>’
Version string
7.6.6 Break
Send a SPACE (DOT if NoisyEnvironment flag is set) to cancel e.g. Continuous Read Mode.