F. USER CALIBRATION 

Under exceptional circumstances it is possible for the scale to lose accuracy and may need re-calibration. 
(The load cell of this precision scale is protected against overloaded weight that is applied slowly, but 
overload caused by dropping the scale or dropping something heavy on the scale may cause the scale to 
require re-calibration).  
 
 

CAUTION

: Please do not attempt any calibration by yourself unless you have a 1 -kilogram weight available.  

If a 1 Kg weight is not used the scale will not operate correctly and will require servicing.  If the scale is 
kept in a colder or warmer environment to the room in which calibration is to take place, it must be left for 
long enough to achieve the same temperature before calibration takes place. 
 
 
To calibrate the scale connect the mains adapter to the scale and mains power supply.  The scale will turn 
on and display ©Elane….  Press the 

UK Special Delivery

 key while this appears in the display. The scale 

will prompt you to remove any weights present on the platform. After the weights have been removed, it 
then prompts you to place a 1-kilogram weight on the platform.  After doing so the scale will automatically 
recalibrate itself.  When it is done, the scale will again prompt you to remove the 1-kilogram weight and 
will then restart automatically once the weight is removed. 

Summary of Contents for POSTAGE UK

Page 1: ...AVAILABLE o Recorded Delivery o International Signed For o International Signed For with Additional Compensation o AirSure o AirSure with Additional Compensation o Saturday Guarantee for Special Delivery services SPECIAL FEATURES 1 Tare Function 2 Domed Keyboard for Tactile Response 3 Strain Gauge Loadcell Technology BASIC TECHNICAL DETAILS Maximum Capacity 2000g Including Tare Accuracy 1 gram Pow...

Page 2: ...details B KEYBOARD C POSTAL SELECTIONS 1 1 st Class Mail Letter Large Letter Packet Press this key to select 1 st Class Mail Service By default pressing this key will select Stamped 1 st Class Letter Press Letter Large Letter Packet key to toggle between 1 st Class Letter 1 st Class Large Letter and 1 st Class Packet services Press the Metered Stamped key to toggle between Stamped 1 st Class and M...

Page 3: ... key for International Surface Mail Letters being sent Outside of Europe D SPECIAL SERVICES 1 Recorded Delivery Press this key to add on the fee for Recorded Delivery to the basic postage of 1 st Class or 2 nd Class services Pressing this key again will cancel the service 2 International Signed For 1 2 Press this key once to add on the fee for the International Signed For service to the basic post...

Page 4: ...ight over 2010 grams including tare weight is placed on the platform b The Scale will display Over on the postage display if any weight over 2000 grams including tare weight is placed on the platform c The Scale will display No Service when the user attempts to enable a special service in a service where it is not applicable d The Scale will display N A if current weight exceeds the maximum allowe...

Page 5: ...le is kept in a colder or warmer environment to the room in which calibration is to take place it must be left for long enough to achieve the same temperature before calibration takes place To calibrate the scale connect the mains adapter to the scale and mains power supply The scale will turn on and display Elane Press the UK Special Delivery key while this appears in the display The scale will p...

Reviews: