System Design

Planning

The VIA!Valet100EM can be installed and placed on almost any 

flat surface such as a desk, table or countertop, or easily mounted 

underneath a cabinet. Because it folds flat, the VIA!Valet100EM can 

be tucked neatly out of view when not in use. Before installing the 

VIA!Valet100EM it is essential to have a detailed and accurate sys-

tem design. Talk with the homeowner to make sure all expectations 

and design goals are explored. The first step to a good design is to 

map the system. It is advisable to mark up a copy of the house floor 

plan with speaker, keypad, touch panel, volume control, and equip-

ment locations, etc. Make sure that all locations are decided upon 

before pre-wiring commences so that all necessary wiring and instal-

lation hardware is in place.

It is essential that ALL system components are accounted for prior 

to the pre-wire stage. After establishing design goals with the hom-

eowner, make a detailed list of all components.  Include source 

equipment, keypads, touch panels, volume controls, amplifiers, com-

munications gear, etc. Gather up any IR remote controls that may be 

necessary for final programming, or ensure that the IR codes for all 

equipment to be installed are available in the VIA!TOOLS IR Library.

When planning specific under cabinet installation locations for 

LCD Touch Panels, please keep the following tips in mind:

When properly installed, nothing should be applying contact pressure to the touch 

• 
panel except for the operator’s finger. If something is touching the touch screen win-
dow, a false signal can be generated causing the touch panel to respond incorrectly.

 Avoid installation in direct sunlight or strong ultraviolet light (such as grow lamps 

• 
for plants). This can degrade or discolor the polyester film.

 

•  Avoid installation over heat generating devices and/or in moist areas where 
condensation can form on the polyester film. Both heat and condensed moisture can 
affect touch screen performance.

 Avoid applying any foreign objects, such as adhesive labels, glue, etc. on the touch 

• 
screen’s polyester film. This can release chemicals that can discolor the clear film.

 

 

 

 

 

 

 

 

 

 

Summary of Contents for VIA! VALET100EM

Page 1: ...100EM Tabletop Under Cabinet 10 Color Touch Panel INSTALLATION MANUAL...

Page 2: ......

Page 3: ...that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off an...

Page 4: ......

Page 5: ...heater 7 Stand Alone Home Theater Expanded 8 ELAN System12 9 ELAN System8 10 ELAN System6 11 RS 232 Controlled Devices Regardless of System Type 12 Installation 13 Pre Wire 13 Control Status Power 13...

Page 6: ...S Page 2 ELAN Home Systems 2008 All rights reserved Sense Port 27 Operation 28 Timeout 28 Video Mode 28 Video Overlays 28 Cleaning 28 Cleaning Mode 29 Troubleshooting 30 Specifications 31 Programming...

Page 7: ...plastic film suspended over a glass panel which is then adhered to the front of a color LCD Liquid Crystal Display screen Depressing the polyester film with a finger allows the film to touch the glas...

Page 8: ...1 2 The display rotates up to 330 from its stow position allowing you to view the display from almost anywhere in the room as shown in Figure1 2 When the VIA Valet100EM is not being used simply rotate...

Page 9: ...m eowner make a detailed list of all components Include source equipment keypads touch panels volume controls amplifiers com munications gear etc Gather up any IR remote controls that may be necessary...

Page 10: ...s or electromagnetic interference such as CRT monitors light dim mers and some power supplies Do not mount the VIA Valet100EM outdoors or in areas exceeding its operating temperature range of 10 F 23...

Page 11: ...a Home Theater controller The diagram below shows a basic application using one VIA Valet100EM a PVIA1 Valet Wall Plate and an ELAN IRD4 Amplified IR Connection Block to control a stack of A V equipm...

Page 12: ...The diagram below shows a VIA Valet100EM A PVIA1 Valet Wall Plate two VIA 70EMs and a PVIA4 Wall Plate controlling a stack of A V gear PVIA4 PVIA 4 VIDEO IN 1 2 3 4 16VDC POWER 9 VDC SENSE INPUTS IR...

Page 13: ...12 The diagram below shows one VIA Valet100EM Touch Panel one PVIA1 Valet Wall Plate four VIA 70EM Touch Panels and a SPP connected to an ELAN S12 S12 PVIA1 Valet SPP IR OUT VIDEO OUT 9VDC PWR9 16VDC...

Page 14: ...a VIA Valet100EM with an S8 The diagram below shows one VIA Valet100EM Touch Panel one PVIA1 Valet Wall Plate four VIA 70EM Touch Panels and an SPP Precision Panel con nected to an ELAN S8 PVIA1 Vale...

Page 15: ...iagram below shows a VIA Valet100EM a PVIA1 Valet Wall Plate four VIA 70EMs and a SPP Precision Panel configured for use with an ELAN S6 PVIA1 Valet S6 PWR4 PWR1 IR OUT VIDEO OUT 9VDC PWR9 16VDC PWR1...

Page 16: ...uch Panels in the system PVIA10 VIA SC4 PVIA4 PVIA 4 VIDEO IN 1 2 3 4 16VDC POWER 9 VDC SENSE INPUTS IR OUT 1 2 3 4 ALL SYS SENSE TO VIA NET 1 2 3 4 SPP RS 232 Devices Stand Alone Systems S12 S8 S6 Sy...

Page 17: ...ll Plate are to be installed The VIA Valet100EM will be powered locally using the included PWR1 Power Supply connected directly to the PVIA1 Valet Wall Plate Video The VIA Valet100EM has both a Video...

Page 18: ...er to the F connector of the coax run The VIA Valet100EM has F connectors on both the VIDEO IN Input and VIDEO OUT Output Video Termination Switch When the video signal coming into a VIA Touch panel i...

Page 19: ...ll cable strain relief clamp Connect the other end to the TO VIA VALET jack on the PVIA1 Valet Wall Plate 3 Optional Local Port Connection The LOCAL port is not normally used with the VIA Valet100EM I...

Page 20: ...cabinet 1 Choose an appropriate mounting location underneath the desired cabinet or shelf 2 Using the provided VIA Valet100EM Adhesive Backed Mounting Template carefully place the template in position...

Page 21: ...et 5 Measure the thickness of the bottom of the cabinet or shelf Select the shortest screw length which will pass completely through the cup washer and cabinet shelf Screw length must protrude from un...

Page 22: ...ASHER 4 VIAValet100EM Bottom Figure 3 7 Base Mounting 7 Make the appropriate cable connections and secure the VIA VALET100 to the cabinet by tightening the four screws DO NOT OVER TIGHTEN Figure 3 8 U...

Page 23: ...LAN s IRD4 Amplified Connection Block Signals originate at the VIA Valet100EM pass through the PVIA1 Valet Wall Plate then travel to the connection block where they are routed to each component NOTE T...

Page 24: ...n Manual for additional details SPP VIA Connector IR 485 485 GND 16V GND 16V SN To Front of PVIA1 Valet 16V GND 16V GND V485 V485 IR ST SNS Z485 Z485 SIR PVIA1 Valet Rear Figure 3 10 S12 Connections 1...

Page 25: ...PVIA1 Valet Wall Plate to the VIA Valet100EM as shown Connect IR RS485 and GND between the PVIA1 Valet Wall Plate and the SPP as shown Multiple VIA s will connect in the same way Please consult the S...

Page 26: ...lease consult the SPP Installation Manual for use of an SPP Precision Panel with a S6 BLUE WHITE BLUE ORANGE WHITE ORANGE GREEN WHITE GREEN BROWN WHITE BROWN 1 2 3 4 5 6 7 8 PIN COLOR CODE FRONT CABLE...

Page 27: ...he External Power Connector In applications where it is not desirable to use a local PVIA1 Valet Wall Plate is is recommended to use 18AWG 2 conductor wire between the PWR1 and the VIA Valet100EM Touc...

Page 28: ...rights reserved Local Interface Port Use this connector when utilizing local control features such as local source control local IR receivers or sense enabled automated sequences Local Interface Port...

Page 29: ...stribution block connected to the IR OUT LOC in two ways 1 Any IR signal that is received from the Local IR Input is sent out of the Local IR Output RJ 45 Port the SYS IR Output RJ 45 Port and the IR...

Page 30: ...d near a TV or an auxil lary IR receiver placed in an area more convenient than the location of the touch panel Any IR signal that is received from the Local IR Input is sent out the Local IR Output R...

Page 31: ...programmed in VIA TOOLS For example use a motion sensor to activate a contact closure and cause automated actions such as system power on drapes closed and lights dimmed Connect SENSE and GROUND to a...

Page 32: ...on EXIT FROM VIDEO MODE is also pres ent These buttons are Autobuilt in VIA TOOLS and will allow the homeowner to display a specific camera or all cameras as desired See VIA TOOLS Help file for more s...

Page 33: ...d on the VIA Valet100EM with a 30 second delay programmed under it This allows the hom eowner to clean the screen without initiating any commands to the system The CLEAN button should be placed in a l...

Page 34: ...ect IR con nections 2 Incorrect or missing IR RS232 commands in VIA TOOLS 1 Verify IR connections and test with IR Emitter with talk back LED 2 Verify commands in VIA TOOLS Unit will activate but disp...

Page 35: ...r Video Loop OUT F connector Power Terminal 2 Pin Local Interface 5 Pin Wiring Requirements Cat 5 Data RG 6 or RG 59 coaxial cable Composite Video Display Graphics Resolution Signal Viewing Angles Hig...

Page 36: ...etween the PC and the touch panel to be programmed It is NOT NECESSARY to power the VIA VALET100EM during programming making it pos sible to program and download to multiple units prior to installatio...

Page 37: ...in an under cabinet application the panel trim bezel Logo may be removed and remounted in a 180 degree configuration 1 Remove 2 screws from rear panel location as shown in Figure C 1 2 Remove Logo ba...

Page 38: ...VIA VALET100EM E LA N H OM E S Y S T E M S Page 34 ELAN Home Systems 2008 All rights reserved Notes...

Page 39: ......

Page 40: ...y ELAN the warranty obligations of ELAN shall in all respects conform to the warranty actually extended to ELAN by its supplier The foregoing warranties do not cover reimbursement for labor transporta...

Page 41: ...0EM LINEAR P N 9905959 REV B 2008 INK BLACK MATERIAL 60 LB WHITE COATED PAPER SCALE 1 1 FLAT SIZE 11 000X8 500 FLAT TOL 40 FOLD ONCE TO 5 500X8 500 SADDLESTITCH ARTWORK CREATED BY ELAN HOME SYSTEMS NU...

Reviews: