Elan ElanDRYER XXL User Manual Download Page 12

 

 

 

– User guide -  

ElanDRYER XXL

 

 

 

 

 

12

 

9.  SAFETY PRECAUTIONS 

 

9.1 Basic safety measures 

 

In order to avoid accidents during normal use, maintenance and troubleshooting 

 

the following shall be respected: 

  earth connections shall be checked periodically; 

  the  operator  shall  command  the  equipment  standing  on  a  clean  and  dry 

rubber sheet 

  the mains power supply protection circuits shall be checked periodically 

  direct contact with possibly hot surfaces shall be avoided 

  Safety equipment must not be put out of operation 

 

 

Attention: 

After disconnection, some power components may still have hazardous 
voltage for 60s. 

 

 

Attention: 

Persons with cardiac pacemaker are not allowed to operate the system.  
When the inductor is swiched on, thay have to keep a safe distance of min 5m. 

 

 

9.2 Basic safety measures during maintenance 

 

o

  during  maintenance  and  troubleshooting  the  low  voltage  protection 

norms shall be respected 

o

  operator,  maintenance  and  service  personnel  shall  be  properly 

instructed 

o

  only  service  person  may  operate  any  troubleshooting  inside  the 

distillation machine 

 

Before doing any maintenance work on the distillation machine: 

  Switch off the distillation machine 

  Wait  60  seconds  after  the  main  contactor  is  off,  to  assure 

complete discharging of the capacitors 

 

 

 

 

 

Summary of Contents for ElanDRYER XXL

Page 1: ...User guide ElanDRYER XXL 1 Elan Dryer XXL...

Page 2: ...User guide ElanDRYER XXL 2 ElanDRYER XXL Polymer Drying machine Type EDM 10KXXL...

Page 3: ...LAN Innovative Technologies SRL make every Attempt to ensure the correctness of this manual no guarantee of correctness is offered or implied Specifications of EDM 10KXXL distillation machine and Soft...

Page 4: ...quipment room W x D x H 3500 x 3000 x 2000 mm Weight 1000 kg Draw number 6 Characteristics Mains supply voltage 380 V 10 50 Hz Max power consumption 10 kW Ambient temperature 10 40 C Noise level 50 dB...

Page 5: ...bient conditions Ambient temperature 10 40 C Maximum relative humidity 80 at 20 C Maximum altitude 2000 m Ambient without unusual fire and explosive hazards no chemically active substances and no elec...

Page 6: ...User guide ElanDRYER XXL 6 3 IMAGES...

Page 7: ...User guide ElanDRYER XXL 7...

Page 8: ...User guide ElanDRYER XXL 8 4 USER INTERFACE Main Screen Drying Status Screen...

Page 9: ...fixed carefully during transport to avoid mechanical damage The equipment shall be handled using the lifting hooks specially built on Transport and storage conditions temperature 25 C 40 C relative hu...

Page 10: ...tection earth The specialists of the manufacturer shall make the machine commissioning The customer s maintenance personnel participation at commissioning is recommended Safety norms for low voltage i...

Page 11: ...V insulation tester electrical documentation and user guide Damaged components shall be replaced with the same type or equivalent Attention Modifications of the rated values and setting values of the...

Page 12: ...nnection some power components may still have hazardous voltage for 60s Attention Persons with cardiac pacemaker are not allowed to operate the system When the inductor is swiched on thay have to keep...

Page 13: ...h off the distillation machine using the main switch Wait 60 seconds after the main contactor is off to assure complete discharging of the capacitors Be sure that all screws are tightened After switch...

Reviews: