© ELAN Home Systems, Inc. 2004 • All rights reserved.  7/04                                                                                  Page 3

D1650/D1651

INSTALLATION MANUAL

ELAN HOME SYSTEMS

RISK OF ELECTRIC SHOCK

        DO NOT OPEN!

 

WARNING

CAUTION:  TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT
REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

WARNING: TO REDUCE THE RISK OF FIRE OR SHOCK, 

DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.

The lightning flash with arrowhead symbol within an equilateral triangle

is intended to alert the user to the presence of uninsulated "dangerous

voltage" within the product's enclosure that may be of sufficient

magnitude to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is intended to alert

the user to the presence of important operating and maintenance

(servicing) instruction in the literature accompanying the appliance.

IMPORTANT SAFETY INFORMATION

Read Information

—All the safety and operating information should be read before the appliance is operated.

Follow Information

—All operating and use information should be followed.

Retain Information

—The safety and operating information should be retained for future reference.

Heed Warnings

—All warnings on the appliance and in the operating instructions should be heeded.

Wall Mounting

—Mounting of this appliance should be done only by an authorized installer.

Ventilation

—The appliances should be situated so that their location or position does not interfere with their proper ventilation.

These appliances should never be placed near or over a radiator or heat register. These appliances should not be placed in a built-in
installation such as a bookcase or cabinet that may impede the flow of air through the ventilation openings.

Non-Use Periods

—Appliances that are left unattended and unused for long periods of time should be de-energized.

Power Sources

—The appliances should be connected to a power supply only of the type described in the operating instruc-

tions or as marked on each appliance. If you are not sure of the type of power supply to your home, consult your authorized ELAN deal-
er or local power company.

Grounding or Polarization

—These audio products must be connected to a grounding-type alternating-current circuit on

a dedicated circuit breaker. This is a safety feature.  The green safety wire from the A.C. circuit must be connected.

Water and Moisture

—To reduce the risk of electric shock or fire, these appliances should not be used near water––for exam-

ple, near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool.

Power Cord Protection

—A.C.Power supply circuits should be routed by a certified electrician only, in accordance with the

NEC standards.

Summary of Contents for D1650

Page 1: ...16 CHANNEL DIGITAL POWER AMPLIFIER I N S T A L L A T I O N M A N U A L A N D U S E R S G U I D E D1650 D1651 SIXTEEN CHANNELS OF DIGITAL COOL...

Page 2: ...ce These sys tems allow people to move room to room control ling centrally located equipment with ease ELAN s product line includes Power Amplifiers Zoned Pre Amps Intelligent Keypads LCD Color Touch...

Page 3: ...tions should be heeded Wall Mounting Mounting of this appliance should be done only by an authorized installer Ventilation The appliances should be situated so that their location or position does not...

Page 4: ...may touch dangerous voltage points or short out parts that could result in a fire or electric shock Care should be taken so that objects do not fall and liquids are not spilled into the appliance thr...

Page 5: ...ty Information 3 System Overview 6 Specifications 6 Features 7 Class T Explained 8 2 Connections and Applications Independent Stereo Zones 9 Two Room Stereo Zones 10 Stereo Zones with Mono Sub Zones 1...

Page 6: ...ors Power AC Power Requirements 120 VAC 1200 Watts Power Supply Ultra high efficiency toroidal transformer Triggers Remote Trigger Inputs 5 to 24 Volts AC DC Trigger Loop Output 12VDC 0 1A Dimensions...

Page 7: ...t 12VDC Trigger Inputs allow each pair of channels to be powered up and muted independent ly The 12VDC Trigger Output turns on and mutes additional amplifiers Signal Presence and Clipping Indicators H...

Page 8: ...mid conduction This mid conduction state is what causes linear switch ing amplifiers to be as inefficient as they are less than 50 efficiency Class D amplifiers are approx imately 85 efficient a 35 in...

Page 9: ...s on a zone by zone or system wide basis Independent Stereo Zones The D1650 is set up to easily power eight independ ent stereo zones right out of the box This is the standard configuration for most m...

Page 10: ...OUTPUTS Two Room Stereo Zone By using the D1650 s Audio Loop an additional pair of speakers can be added to a zone In this example both pairs of speakers will ramp volume up and down simultaneously T...

Page 11: ...utput to Line Inputs 1 2 Line Outputs 1 2 to RCA Y Cable RCA Y Cable to Line Input 3 All Speakers Volume Ramps Up Down Together Speaker Outputs Coincide w Line Inputs Stereo Zones w Mono Sub Zones Use...

Page 12: ...area such as hallways L shaped rooms kitchens and outdoor areas The use of mono zones also increases the capacity of the amplifier up to sixteen mono areas can be powered from one D1650 In this examp...

Page 13: ...Room Controller ZONE OUTPUTS Bus Modes The D1650 s unique Bus Mode feature allows multi ple amp Inputs to be internally configured to several different Outputs This increases the amp s flexibili ty wi...

Page 14: ...urce can be used As in the ALL ON example any 3 24 Volt AC or DC source may be used to trigger these specific inputs This application gives additional control in advanced systems Examples include Zone...

Page 15: ...r all channels Please Note Whenever the Front Display is lit dur ing volume adjustment for example ACE clipping elimination circuitry is disabled Lockout Mode The Lockout feature is designed to disabl...

Page 16: ...1 Turn the D1650 OFF using the rear Power Switch 2 Turn the unit back ON The Front Display will read ELAN 3 Press and hold C C V and V all the front panel buttons at once while ELAN is dis played 4 Th...

Page 17: ...pedance condition Correct overheating or AC power issues Once issue is found and resolved cycle power to D1650 This condition could be caused by 1 2 3 and or 4 above Audio Hum 1 Ground Potential Diffe...

Page 18: ...Not Power Up 1 Power Switch is OFF Turn it ON Switch is Located on Back of Unit 2 Circuit Breaker Tripped ELAN Recommends the D1650 be Installed on its Own 15 Amp Circuit Breaker Placing this Unit on...

Page 19: ...ELAN Home Systems Inc 2004 All rights reserved 7 04 Page 19 D1650 D1651 INSTALLATION MANUAL ELAN HOME SYSTEMS ELAN Home Systems Inc 2004 All rights reserved 7 04 Page 19 Notes...

Page 20: ...by ELAN the warranty obligations of ELAN shall in all respects conform to the warranty actually extended to ELAN by its supplier The foregoing warranties do not cover reimbursement for labor transpor...