ELAD DUO-ART 60
User Manual - Rev. 1.3 - 04/2018
© 2018 ELAD S.r.l. All rights reserved. No part of this document may be reproduced, published, used, disclosed or disseminated
in any form or by any means, electronic, photocopying or otherwise, without prior written permission of ELAD S.r.l.
12
Name
Type
Code
Description
Error
E-410
Error generated by a too high SWR. This is a hardware
protection.
Error code: ST-P2-b1.
Error
E-420
The current absorbed by the DUO-ART has exceeded the
maximum threshold.
Error code: ST-P9-b0.
Error
E-421
The calculated reflected power has exceeded the
maximum threshold.
Error code: ST-P9-b1.
Error
E-422
The calculated forward power has exceeded the maximum
threshold.
Error code: ST-P9-b2.
Error
E-423
The input power of the DUO-ART has exceeded the
maximum threshold.
Error code: ST-P9-b3.
Error
E-440
Set filter selection error. This error is generally due to an
incorrect frequency setting.
Error code: ST-P10-b0.
Error
E-441
Error regarding the input power of the amplifier. The
input power may be too high or the PTT input may not be
connected properly.
Error code: ST-P10-b1.
PWR IN
error
Error
FILTER TX
Error
SENS PW
Error
FWD
Error
REFL
Error
I OUT
HI SWR
error