STEP 4:  RECOMMENDED RESERVOIR CONFIGURATION 

 

EK-RES X3 Lite series reservoir features 1 (one) G1/4 threaded inlet/outlet openings on the Reservoir Bottom plus additional 3 (three) on the Reservoir Top.

 

In 

order for reservoir to function properly one port must be used as an inlet and one as an outlet. Unused ports must be closed with plugs using enclosed 6mm 

Allen key! 

 

GENERAL OVERVIEW OF ALL G1/4 THREADED PORTS:

 

 

 

 

 

 

OTHER RECOMMENDED RESERVOIR CONFIGURATION

 

 

REQUIRED TOOLS AND ACCESSORIES: 

 

 philips screwdriver      

power drill with 4mm drill bit (optional)

 

 

1

- Vertical Port

 

2

- Vertical Port

 

3

- Vertical Port

 

4

- Vertikal Port  (bottom)

 

RES X3 Lite in Horizontal position

 

RES X3 Lite in 
Vertical position (PE- 
foam recommended) 

 

RES X3 Lite in 
Vertical upside 
down position

 

Inlet

 

Inlet

 

Outlet

 

Outlet

 

Inlet

 

Outlet

 

EK-Plug G1/4

 

Allen Key 6mm

 

RECOMMENDED RESERVOIR CONFIGURATION: 

EK-ACF fitting 

Tubing 

IMPORTANT NOTES: 

1.

 

When using ports #2, #3 or #4 it is mandatory to use the enclosed 

EK-Extender G1/4 

(EAN: 3831109845165) due the ports being recessed into the plastic Reservoir Bottom and 

Top. 

2.

 

When  using  EK-Extender  G1/4  make  sure  not  to  use  fittings  or  barbs  with  G1/4 thread 

longer than 5mm! All 

EK-ACF 

and 

EK-HDC 

fittings are compatible! 

3.

 

When using ports #1, #2 and #3 make sure not to use fittings or barbs with diameter 

larger than 25mm! All 

EK-ACF

 and 

EK-HDC 

fittings are compatible! 

4.

 

EK recommends the use of EK-ACF fittings. When using fittings other than EK-ACF series 

please use hose clamps or appropriate substitute to secure the tubing to the barb. The use 

of biocide containing and corrosion inhibiting coolant is always recommended for any liquid 

cooling system. 

TIPS AND ADVICES: 

-

 

Using a horizontal pass-through configuration (using ports #1 as outlet #4 as inlet) will 

yield in most optimal hydraulic conditions but may result in difficult initial bleeding of air in 

low restriction- or high pumping power water cooling systems. 

-

 

When using a top feeding vertical configuration (using ports #1 and #4 as inlet/outlet) you 

may experience severe vortex issues. Using a PE foam as will remedy this issue. Please see 

STEP 3! 

 

To connect RES X3 Lite with XTOP Revo Dual 
D5 you need to use enclosed Male-Male Extender. 
Extender have threat longer than 5mm!!!        
NOT compatible with EK-XTOP DDC!!! 

 

 

 