background image

- 5 -

WATER BLOCK DIMENSIONS

278.4 mm

267 mm

134.2 mm

104.3 mm

97 mm

19.5 mm

134.2 mm

97 mm

13.6 mm

46.5 mm

75.5 mm

Summary of Contents for EK-PRO GPU WB RTX A100

Page 1: ...USER GUIDE GPU WATER BLOCK EK PRO GPU WB RTX A100 ...

Page 2: ...CB EK Fittings require only a small amount of force to screw them firmly in place since the liquid seal is ensured with the rubber O ring gaskets The use of quality market proven corrosion inhibiting coolants is always strongly recommended for any liquid cooling system Do not use pure distilled water as a cooling liquid For best results EK recommends the use of EK CryoFuel Coolants Make sure to bl...

Page 3: ... STOCK COOLER 7 CLEANING THE PCB 7 CUTTING AND PLACING THERMAL PADS 8 APPLYING THERMAL COMPOUND 8 INSTALLING THE WATER BLOCK 9 PLACING THE BLOCK ON THE GRAPHICS CARD 9 ATTACHING THE WATER BLOCK 9 CHECKING THE CONTACT IN CASE OF HIGH TEMPERATURES 11 INSERTING THE GRAPHICS CARD INTO THE CHASSIS 12 TESTING THE LOOP 12 SUPPORT AND SERVICE 13 SOCIAL MEDIA 13 ...

Page 4: ...M3x6 DIN 7991 2x 9029 Thermal PAD F 1 0mm 120x16mm 2x 3830046996732 Screw M3x4 DIN7985 2x 8123 EK TIM Ectotherm 1g 1x 3830046998446 Screw M3x6 ISO 14581 TX INOX 2x 103090 Screw UNC 6 32x5 1x 8483 EK Pro GPU WB RTX A100 Ni Inox 1x 3831109847961 Washer POLYAMID M2 5 0 7mm with self adhesive tape 2x 8627 Thermal PAD G 1 0mm 120x24mm 2x 3830046996770 120 mm 16 mm Washer POLYAMID M2 5 0 5mm 16x 8623 Sc...

Page 5: ... 5 WATER BLOCK DIMENSIONS 278 4 mm 267 mm 134 2 mm 104 3 mm 97 mm 19 5 mm 134 2 mm 97 mm 13 6 mm 46 5 mm 75 5 mm ...

Page 6: ...03090 Screw M3x6 ISO 14581 TX INOX 21 6 100845 Spacer M4 M2 5x2 5 HEX 8 7 103767 top acetal FC terminal Direct 2x G1 4 1 8 103713 054 metal power adapter 1 9 103705 055 metal RTX A100 Pro Top Inox 1 10 100006 Screw M4x27 DIN7984 3 11 5155 OR 15x1 EPDM50 FC Terminal 2 12 102490 Medenina Pro GPU Bracket standoff M4 6 32 Ni 1 13 8625 Washer POLYAMID M2 5 0 7mm with self adhesive tape 2 11 3 9 1 13 6 ...

Page 7: ...ing steps in order to install the EK Pro GPU RTX A100 water block onto the graphics card STEP 2 CLEANING THE PCB Wipe off the remains of the original thermal compound using a nonabrasive cloth or Q tip as shown in the sample image until the components and circuit board are completely clean EK recommends the use of denatured alcohol for removing TIM leftovers After that remove all remaining stock t...

Page 8: ...tity of thermal pads to complete this Step You must remove the protective foil from both sides of the thermal pad before installation Thermal Pad F 1 0 mm Thermal Grease Apply the enclosed EK TIM Ectotherm thermal grease thermal compound on the GPU heat spreader IHS as shown in the image The layer of the thermal compound must be thin and even over the entire surface of the IHS The excessive or une...

Page 9: ...e too much force when pressing the block down to the PCB since chip dies are prone to cracking STEP 1 For this Step you will need M 2 5 PVC Washer 8 pcs M2 5 x 4 AX1 Screw 8 pcs 4 mm STEP 2 STEP 2 ATTACHING THE WATER BLOCK Use eight 8 M2 5 x 4 AX1 screws and M2 5 PVC washers Tighten the screws evenly using the Phillips head screwdriver EK recommends you start tightening the screws around the GPU c...

Page 10: ... cable with mounting it into included inox power adapter STEP 4a Stick the two included plastics pads M3 on to inox power addapter as shown on picture STEP 4b Insert 8 pin power connector in to the inox adapter Pads on the power adapter must be alligned with openings in inox power adapter Pay attention to the orietation of the latch on connector ...

Page 11: ...whether the water block makes contact with the intended integrated circuit Then repeat Steps from the previous section to re attach the block In case you fail to obtain good contact please check again or contact our support service at https www ekwb com customer support Screw M3x6 DIN 7991 2x 9029 Allen Key 2mm 1x 8901 STEP 4c STEP 4c Fasten a inox power adapter to the water block with two M3x6 sc...

Page 12: ...the water block assembly that might damage your card or water block To ensure the installation of EK components was successful we recommend you perform a 24 hour leak test When your loop is complete and filled with coolant connect the pump to a PSU outside your system Do not connect power to any of the other components Turn on the PSU and let the pump run continuously Inspect all parts of the loop...

Page 13: ...ge with TECHNICAL SPECIFICATIONS AND WATER BLOCK PARTS where you can find the EAN number of each part you might need Include the EAN number with quantity in your request Mounting Mechanism EAN can be found under BOX CONTENTS Thermal pads are readily available in the EK shop EKWaterBlocks EKWaterBlocks ekwaterblocks ekwaterblocks EKWBofficial SUPPORT AND SERVICE SOCIAL MEDIA ...

Reviews: