ekwb EK-FC R9-295X2 Installation And Mounting Manual Download Page 2

All disclosures, notices and warranty conditions are being written on the EKWB website. Please read terms of use.                                                          Released on 24

th

 of May, 2014. Revision 1.0 

2.

 

Remove  two  hexagonal  nuts  securing  the  original  two-slot  I/O  bracket  to  the 

circuit  board.  Remove  the  screw  that  secure  the  tab  of  the  I/O  bracket  to  the  circuit 
board as well. Replace the original I/O bracket with enclosed EK-FCS10000 single-slot 

I/O  bracket  and  install  it  using  two  original  hexagonal  nuts.  Secure  the  bracket  tab 
using M3x4 DIN7985 screw. 

 

 

3.

 

PLACING BLOCK TO GRAPHIC CARD

. Carefully position the water block 

with preinstalled 2.5mm standoffs on to the graphics card. During this process please 

make sure you align mounting holes on PCB with holes on the water block. Also pay 
attention not to use too much force by pressing block down to PCB. Chip dies are 

prone to cracking. 

 

 

 

STEP 5:  INSTALLATION OF FITTINGS AND TUBING

 

4.

 

ATTACHING BLOCK TO GRAPHIC CARD

. By using Philips screwdriver, screw 

in enclosed M3x4 DIN7985 screws. EKWB recommends start screwing the screws 

around the GPU core using Philips head screwdriver and continue outwards. Do not 
forget to put a PVC washer under each screw!

 

 

 

Screw in the two G1/4 threaded male fittings. Attach the liquid cooling tubes and 
connect the water-block(s) into the cooling circuit. 

EKWB recommends using EK-

CSQ fittings with the EK-FC R9-295X2 series water blocks

. To ensure that the 

tubes are securely attached to the barb/fittings, please use hose clamps or an 

appropriate substitute. 
 

You can use any opening as an inlet/outlet port. 
 

CAUTION:

 In case of using connectors other than EK-CSQ or EK-PSC series 

compression fittings, take special attention to the length of the fittings’ male G1/4” 
thread. In case the thread is longer than 5 mm please use the enclosed 1.8 mm nickel 

plated spacer! 
 
5mm is the maximum allowed G1/4” thread length! 

 

 

STEP 4:  CHECKING FOR CONTACTS 

Temporarily remove the water block to check for uniform surface contact between the block and the components, pay special attention to the VRM section of the graphics card. 
Check whether the water block makes contact with the VRM. Then repeat sub-steps in previous section to re-attach the block. 

In case you fail to obtain good contact, 

please check again your thermal pad thickness or contact our support service.

 

STEP 7:  INSERTING CARD IN YOUR PC CASE 

 

Carefully lift your graphics card with installed block and insert it in your PC’s motherboard PCI-express expansion slot. Please bear in mind that your graphics card is probably 
heavier than when it was equipped with original heat sink fan assembly. One needs to be very careful when handling the graphics card. Avoid all un-needed manipulation of the 

VGA/water block assembly that might damage your card or water block during final installation.

 

REQUIRED TOOLS AND MOUNTING SCREWS: 

 

   scissors             

 philips or torx T6 screwdriver 

 

M3x4 DIN7985 screw 

PVC washer 

Factory enclosed hexagonal nuts 

M3x4 DIN7985 screw 

PVC washer 

EK-CSQ Fitting 

Tubing 

EK-Plug G1/4 

Acetal Terminal 