Released on 05
th
of October, 2015
You can use any G1/4 threaded ports marked as an outlet port except for the inlet port which is clearly marked (“IN”). We recommend using the 2
nd
outlet port right beneath the J-shaped plastic extrusion which eases the air bleeding process significantly. Make sure unused outlet ports are plugged
with enclosed plugs.
STEP 5: FILL THE RESERVOIR
Fill reservoir through G3/8 threaded fill port (marked with arrow) and make sure liquid is not spilled over your computer or any electrical devices nearby.
Preferably, your pump's height level should be lower than that of the EK-DBAY Spin Reservoir in order to flood and prime the water pump. Run your pump
shortly for couple of times to make sure water floods your tubes and other water cooling components. Repeat the procedure until you are done and pay attention
to the water level in your reservoir. Ideally there should be only so much water to make waterfall effect still noticeable in the reservoir. Lowest and highest
recommendable water levels are indicated on the reservoir's front panel (
min
,
max
). Once done with filling please close your EK-DBAY Spin Reservoir with G3/8
plug and tighten the seal using enclosed allen key.
STEP 5: OTHER INSTRUCTIONS
Please note that EKWB holds no responsibility of any kind if assembly is not performed as per instructions. This applies also for
all products that are not listed as compatible on web page. Users must by all means also consider instructions that are being
made for proper use of pump and other water cooling components/liquids provided by manufacturer(s).
HINT: Never let your pump running dry. Prolonged dry use enhances the risk of damaging the pump’s bearing thus rendering
pump useless.