background image

Quick Index

Settings

Steps

Pairing 

Switch Rotating Direction

Upper and Lower Limits Setting 

Adjust Limits

P1 (hold down 2s) → 

Stop (hold down 2s)

Up + Down (hold down 2s)

Set upper limit    

Up (hold down 2s)  → Up + Stop (hold down 2s)

Adjusting the upper limit

Up + Stop (hold down 5s)  → Up or Down → Up + Stop (hold down 2s)

Adjusting the lower limit

Down + Stop (hold down 5s) → Up or Down → Down + Stop (hold down 2s)

Acceleration setting

P2 → Up → Up 

Deceleration setting

P2 → Down → Down

Set lower limit

Down (hold down 2s)  → Down + Stop (hold down 2s)

P2 → Stop → Stop 

5

Add / Remove Preferred Position

4

3

2

1

Jog Mode & Running Mode Switch

Pair / Unpair Additional Emitter

Up + Down (hold down 5s) → Stop

P2(a) → P2 (a) → P2(b)

P2(a) → P2 (a) → Stop (b)  (hold down 2s)

P1 (hold down 2s) → 

Stop (b)  (hold down 2s)

6

7

8 Speed Regulation

Troubleshooting

Issues

Possible causes

Solution

The motor has

no response 

emitter battery is low capacity

Replace battery

Out of radio control range

Try control within closer range

The emitter cann't

control single motor

Multiple motors are paired to the

same channel. 

Pair single motor with emitter correctly
Try to use multi-channel emitters to control multi-motor

projects, ensure each channel to control one single motor

The motor doesn't run or starts

too slowly or make loud noise 

The motor stops during the

up and down running

Connections are incorrect.

Check connections

Installation is improper or overload 

The motor has reached the upper limit

or lower limit

Adjust the new upper limit or lower limit

Check installation or overload

Radio interference / shielding

Check antenna on motor is intact and exposed. Check for

possible source of radio interference. 

Power failure or incorrect connection

Double check power and cable connections, follow wiring

instructions. 

Battery in motor is depleted

Charge with the corresponding charger or solar panel

Please read following points of attention carefully before setting.

Setting Notice

Important Safety Instructions To Be Read Prior To Operation.

Essential Settings

The steps in factory mode must be completed to ensure proper operation.

1. Don’t operate motors when low voltage alarm.
2. Operation

    

 The valid interval time of the buttons is within 10S, if there is no operation within 10S, the emitter

    will exit the present setting.
    

 The motor will jog and beep as hint, pls operate after the jog and beep.

3. Set the limit position

    

After the upper / lower limit setting, and the upper / lower limit positin can’t at the same position.

    

After the limit setting, with power off and memory function.  

    

Limit delete will clear all limit memory.

    

It will exit limit setting when program there is no operation for 2 minutes.

4. If the emitter lost, please set up again with the new emitter.
5. One motor can store maximum 10 channels; after fully stored, if pair new channels, only the last one
    will be covered circularly.

Button Instructions

Charger port

and solar panel

charging port

P1 button

P1

Functions of P1 button

1. Cycle Operation: Press P1 button once and every press the motor will run upward → stop → downward circulary.
2. Pairing or Pair / unpair Additional Emitter: Press P1 button for 2S, motor jog once, release button and long beep once, motor
    is ready for pairing or pair / unpair additional emitter. 
3. Radio Lock: Press and hold P1 button for 6S, the motor will jog twice, release button and beep twice, the motor enters radio
    lock status, the motor won't receive any signal; press P1 button once to disable Radio Lock.
4. Switch Direction: Press and hold P1 button for 10S, the motor will jog 3 times, release button and beep 3 times, the running
    direction of the motor has been changed. 
5. Reset to Factory Mode: Press and hold P1 button for 14S, the motor will jog 4 times, release button and beep 4 times, the
    motor has been reset to factory mode.At this point the motor will go into deep sleep. After entering deep sleep, the motor
    can't be controlled. At this time, you need to press P1 button for 2S and then the motor turns to prompt to exit deep sleep.

* The operation is only valid when there is no limits. If the motor has already set the upper and lower limit, then

  you can only switch direction by P1 button.

2  Switch Rotating Direction

 (Optional)

+

UP

DOWN

If press UP, the motor runs downward, try below to switch direction

Press and hold UP and DOWN buttons simultaneously for 2S

(1 jog

 and 1 beep

)

, the direction has been switched successfully.  

* If within 10S, the motor doesn't receive STOP signal from the any emitter, it will exit the paring mode automatically.

1  Pairing 

Factory mode

Press P1 button for 2S (1 jog ),  release button and make a long noise, 

within 10S, press STOP for 2S (2 jogs and 3 beeps ), the motor has

been paired successfully.

STOP

P1

P1

1  

Add A Preferred Position

User mode

1  Set preferred position

P2

P2

STOP

STOP

Check both upper and lower limits are set. Operate the

product to desired preferred position. Press P2 (1 jog

and 1 beep), press STOP(1 jog and 1 beep), STOP

again (2 jogs and 3 beeps), the preferred position is set.  

2  Remove preferred position 

P2

P2

STOP

STOP

Press P2 (1 jog

 and 1 beep

), press STOP (1 jog

and 1 beep

),  STOP again(1 jog 

and long beep

once

), the preferred position is deleted.

* In the normal running mode, if the motor is not at the preferred position, press STOP button longly, then the motor

  will run directly from the current position to the preferred position ( apply for roller systems); In the jog mode, press

  STOP button longly, firstly, the motor runs from the current position to the lower limit then to the preferred position

  (apply for cord-lifting system).

Press UP for 2S, operate the motor to desired upper

position, press and hold UP and STOP buttons

simultaneously for 2S (2 jogs and 3 beeps), upper

limit is set.   

3  Upper and Lower Limits Setting 

1  Set upper limit    

+

UP

UP

STOP

* If exit the limits setting status before you finish the limit setting, then the motor will take the previous limits if has;

  After the limits have been set successfully, the motor will enter the user mode.

Press DOWN for 2S, operate the motor to desired

lower position, press and hold DOWN and STOP

buttons simultaneously for 2S (2 jogs and 3 beeps),

lower limit is set.   

2  Set lower limit

DOWN DOWN

STOP

+

* After entering the limits fine tuning mode, the original 

preferred position

 will not be deleted; If there is no button

  operation within 2 minutes, it will arrive within 2 minutes, and the motor will turn to prompt, and automatically exit

  the route adjustment mode.

* When in jog mode, press UP or DOWN once, the motor will be jog running, if press more than 2 second, the motor

  will be continously running.

2  

Jog Mode & Running Mode Switch

DOWN

STOP

UP

+

Press and hold UP and DOWN buttons simultaneously for 5S (1 jog),

press STOP (

1 jog 

and long beep once), switch to jog mode, If motor

jog twice and beep 3 times, switch to running mode.

3  Adjust Limits

1  Adjusting the upper limit

DOWN

UP

or

+

UP

STOP

+

UP

STOP

The new upper

limit position

Press and hold UP and STOP buttons for 5S (

1 jog 

and long beep once), operate the product to desired new

upper limit position, press and hold UP and STOP buttons for 2S(2 jogs and 3 beeps), the new upper limit is

programmed successfully.        

2  Adjusting the lower limit

Press and hold DOWN and STOP buttons for 5S (

1 jog 

and long beep once), operate the product to desired

new lower limit position, press and hold DOWN and STOP buttons for 2S (2 jogs and 3 beeps), the new

lower limit is programmed successfully.        

DOWN

UP

or

+

DOWN

STOP

+

DOWN

STOP

The new lower

limit position

P2

P2

P2(a)

P2(a)

P2

P2(b)

4  Pair / Unpair Additional Emitter

• Repeat same procedure will unpair additional emitter.

Press P2 (1 jog and 1 beep) and P2 (1 jog and 1 beep)  on existing emitter,

press P2 on new emitter to add (2 jogs and 3 beeps), new emitter is paired

to the motor.  

Method one

Press P2 (1 jog and 1 beep) and P2 (1 jog and 1 beep) on existing

emitter, press STOP on new emitter for 2S to add (2 jogs and 3

beeps), new emitter is paired to the motor.  

Method two

P2

P2

P2(a)

P2(a)

STOP(b)

P1

P1

* (a) as existing emitter,(b) as new emitter to pair/unpair;

  All the setting of the motor will be kept after addiing the new emitter.

• Repeat same procedure will unpair additional emitter.

Press P1 button for 2S (1 jog), release button and long beep once,

press STOP on new emitter for 2S to add (2 jogs and 3 beeps), new

emitter is paired to the motor.  

Method three

STOP(b)

Press P2 (1 jog and 1 beep), UP (1 jog and 1 beep), UP again

(

2 jogs

 and 1 beep), the motor running speed is accelerated.

P2

P2

UP

5  Speed Regulation

UP

1  Acceleration setting

* DM45LE/S does not have this function; If the motor no response, it has already been the Max. or Min speed;

  The factory default is the fastest.

Press P2 (1 jog and 1 beep), DOWN (1 jog and 1 beep), DOWN

again (2 jogs and 1 beep), the motor running speed is decelerated.

P2

P2

DOWN

DOWN

2  Deceleration setting

-3-

-5-

-4-

Lithium Cell

3V

P2

P2

UP

LCD

STOP
DOWN

Channel

sel”

(P1+)

P2

Channel

selection“-”

(P1-)