PRODUCT MAINTENANCE
03/2022
69
NP-DK50 2V 50, 2x2V 110-AD-A-1_03-2022
Venting compressed air poses an injury hazard.
Wear safety glasses when inspecting a safety valve.
22.7. Inlet filter replacement
Inlet filter replacement:
Remove the locking spring (2).
Pull out the rubber plug by hand (2).
Remove the dirty intake filter (1).
Insert a new filter and replace the
rubber plug.
Pre-filter replacement:
Pull out the pre-filter by hand (3).
Replace with a new one and insert it
back.
Fig. 25: Inlet filter replacement
22.8. Procedure for connecting a compressor disconnected from the cabinet
Prior to any maintenance or repair work, switch off the compressor and
disconnect it from the mains (pull out the mains plug).
The compressor (without cabinet) requires that the jumper is always mounted in the terminal strip
for correct operation (Fig. 26, Fig. 27 pos. D). It then replaces the switch on the cabinet.
If there is no jumper in the terminal strip of the compressor (disconnected from
the cabinet), the compressor will not work!
If the cord between the compressor and the cabinet becomes disconnected (by pulling the mains
plug) and the compressor is removed from the cabinet, the compressor will not be functional. This
is why it is necessary to first create a connection to the terminal strip with a jumper (replacing the
circuit breaker function) (Fig. 26, Fig. 27 pos. A).
PROCESS:
Jumper installation (A-B-C-D process)
Disconnect the product from the mains by pulling the plug out of the socket.
Remove the cover on the electrical panel (on the compressor).
The jumper is not in the terminal strip
– A.
Lift up the fuse cover
– B.
Insert the jumper into the terminal strip
– C.
Close the fuse cover
– D.
Reinstall the cover on the electrical panel.
Connect the device to the electrical mains.
Summary of Contents for DK50 2V/50/M
Page 1: ...N VOD NA POU ITIE SK USER MANUAL EN BENUTZERHANDBUCH DE...
Page 2: ......
Page 4: ...CONTENTS 5 INHALT 76 OBSAH 146...
Page 18: ...PRODUCT DESCRIPTION NP DK50 2V 50 2x2V 110 AD A 1_03 2022 18 03 2022 B DK50 2x2V 110S M...
Page 89: ...PRODUKTBESCHREIBUNG 03 2022 89 NP DK50 2V 50 2x2V 110 AD A 1_03 2022 B DK50 2x2V 110S M...
Page 158: ...POPIS V ROBKU NP DK50 2V 50 2x2V 110 AD A 1_03 2022 158 03 2022 Obr 4 Skrinka A DK50 2V 50S M...
Page 159: ...POPIS V ROBKU 03 2022 159 NP DK50 2V 50 2x2V 110 AD A 1_03 2022 B DK50 2x2V 110S M...
Page 218: ......
Page 219: ......
Page 220: ...NP DK50 2V 50 2x2V 110 AD A 1_03 2022 112000519 000...