AD DRYER
03/2022
55
NP-DK50 2V 50, 2x2V 110-AD-A-1_03-2022
Operator’s position. No specific operator’s position is required. The operator may remain within
range of a visual warning signal depending on actual operating conditions.
Low pressure
. This signal is active when the dryer pressure sensor reads low pressure in the
dryer under the defined limit of 3 bar. An air leak from the compressor/dryer, malfunction of the
control solenoid valves on the dryer or a software error may activate this alarm during operation.
High pressure
. This signal is active when the dryer pressure sensor reads an increase in
pressure over the high limit. The air pump will then shut down and remain shut-down until the
pressure decreases. If the air pump does not shut down, excess pressure is vented by the safety
valve on the compressor’s air tank.
High dew point
. This signal is active when the dew point sensor reads a high dew point value.
Expiration of service interval
. This signal is activated until service is performed and the interval
reset, or a new service interval is entered.
19. USER INTERFACE/SETTINGS
19.1. Meaning of symbols on the display
Symbol representing the user manual, or to read the user manual.
Symbol expressing the ambient temperature (from 25
o
C) related to the selected
mode.
The program adjusts the chamber pre-filling in the given mode.
Symbol expressing the ambient temperatu
re (from 25°C to 30°C) related to the
selected mode.
The program adjusts the chamber pre-filling in the given mode.
Symbol expressing the ambient temperature (over 30°C) related to the selected
mode.
The program adjusts the chamber pre-filling in the given mode.
Back to the main menu on the 4 main screens.
Go back.
Symbol for the service interval.
Symbol for when the dryer chamber is currently in regeneration.
Symbol for when the dryer chamber is currently drying.
Summary of Contents for DK50 2V/50/M
Page 1: ...N VOD NA POU ITIE SK USER MANUAL EN BENUTZERHANDBUCH DE...
Page 2: ......
Page 4: ...CONTENTS 5 INHALT 76 OBSAH 146...
Page 18: ...PRODUCT DESCRIPTION NP DK50 2V 50 2x2V 110 AD A 1_03 2022 18 03 2022 B DK50 2x2V 110S M...
Page 89: ...PRODUKTBESCHREIBUNG 03 2022 89 NP DK50 2V 50 2x2V 110 AD A 1_03 2022 B DK50 2x2V 110S M...
Page 158: ...POPIS V ROBKU NP DK50 2V 50 2x2V 110 AD A 1_03 2022 158 03 2022 Obr 4 Skrinka A DK50 2V 50S M...
Page 159: ...POPIS V ROBKU 03 2022 159 NP DK50 2V 50 2x2V 110 AD A 1_03 2022 B DK50 2x2V 110S M...
Page 218: ......
Page 219: ......
Page 220: ...NP DK50 2V 50 2x2V 110 AD A 1_03 2022 112000519 000...