Issue Cause What to do
After installation,
the unit doesn’t
work.
2. The power line and the cable locking connector
is not connecting properly.
2. Check the power connection with the unit is
connected properly.
3. The switch board and control board wirings
are
d
isconnected.
3. Make sure the wirings between the switch
board and control board are connected
properly.
4
. The switch board or control board is defective.
4
. Change the switch board or control board.
Light works,
but motor is
not turning.
1. The motor is defective, possible seized. 1. Change the motor.
2. The thermally protected system detects if
the motor is too hot to operate and shuts
the motor down.
2. The motor will function properly after the
thermally protected system cool down.
3. Damaged capacitor. 3. Change the capacitor.
4. The
switch
board or control board is
defective.
The unit is
vibrating.
1. The motor is not secure in place. 1. Tighten the motor in place.
2. Damaged blower wheel. 2. Replace the blower.
3. The hood is not secured in place . 3. Check the installation of the hood.
4. The switch board or control board is defective.
The motor is
working, but the
lights are not.
1. Defective halogen bulb. 1. Change the halogen bulb.
2. The light bulb is loose. 2. Tighten the light bulb.
The hood is
not venting out
properly.
1. The hood might be hanging to high from the
cook top.
1. Adjust the distance between the cook top and
the bottom of the hood within
26”
and
36
”
range.
2. The wind from the opened windows or
opened doors in the surrounding area
are affecting the ventilation of the hood.
2. Close all the windows and doors to eliminate
the outside wind ow.
3. Blockage in the duct opening or duct work. 3. Remove all the blocking from the duct work
or
duct opening.
4. The direction of duct opening is against the wind.
5. Using the wrong size of ducting. 5. Change the ducting to correct size.
Metal lter is
vibrating.
Troubleshooting
Troubleshooting
TROUBLESHOOTING PROCEDURES FOR EVL
1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s
power is ON.
4. Adjust the duct opening direction.
1. Metal lter is loose. 1. Change the metal filter.
4. Change defective part.
4. Change defective part.
13
Summary of Contents for EFL30GW
Page 2: ......
Page 4: ...IMPORTANT SAFETY NOTICE IMPORTANT SAFETY NOTICE 2...
Page 7: ...5 Installation Installation Hood Specifications ESQ 30 36 SW ESL 30 36 SW BW...
Page 8: ...6 Installation Installation Hood Specifications EFL 30 36GW...
Page 9: ...7 Installation Installation Hood Specifications EVL 30 36SW...
Page 16: ...EVL30SW ESL30SW ESL30BW EVL36SW ESL36SW ESL36BW EFL30GW EFL36GW ESQ30SW ESQ36SW...
Page 17: ......
Page 18: ...R A N G E H O O D PACIFIC RANGE HOOD LTD T O L L F R E E 1 866 808 8008 Printed in Conada...