![EKF SC6-TANGO User Manual Download Page 47](http://html1.mh-extra.com/html/ekf/sc6-tango/sc6-tango_user-manual_2373800047.webp)
SC6-TANGO • CompactPC® Serial • Intel® Atom™ E39xx Processor (APL-I SoC)
Read/Clear Status Register 0
Write:
SMBus Address 0xB0
Read:
SMBus Address 0xB1
Bit
Description CMD_STAT0
7
PF18S
0=Normal operation
1=Last system reset may be caused by a power failure of the +V1.8S voltage regulator
6
RESERVED
Always read as 0
5
RESERVED
Always read as 0
4
PF135S
0=Normal operation
1=Last system reset may be caused by a power failure of the +V1.35S4 voltage regulator
3
RESERVED
Always read as 0
2
RESERVED
Always read as 0
1
RESERVED
Always read as 0
0
RESERVED
Always read as 0
The bits in this register are sticky, i.e. their state will be kept even if a system reset occurs. To clear
the bits a write to the register with arbitrary data may be performed.
©
EKF
-
47
-
ekf.com