en
│
47
The switching duration for the relay can be set up to 99.9 in 0.1-second
increments. Enter the required relay switching duration in tenths of a
second. E.g.:
60
for 6 sec;
100
for 10 sec;
300
for 30 sec. By default,
the switching duration is set to 3 seconds. When the time is set to
0
, the
relay operates as a switch: The relay changes its switching status when a
user code is detected and it remains in that status until another user code
is detected.
The relay switching duration is set via the Admin menu. Enter the admin
code to access the Admin menu.
See
”, page
The system is in the Admin menu.
Step
Action
Description
Display
1st
Press
5
,
3
, then the
number of the relay
(
1
or
2
) and the
value
of the required
relay switching
duration. E.g.,
1
,
0
,
0
for 10 sec.
Status LED lights
up green on the
left.
2nd
Press
✓
.
Status LEDs light
up green.
Status LEDs light
up red.
Something has been
entered incorrectly.
The relay switching
duration was not
changed. Enter the
admin code from the
beginning again.
-
-
3rd
No action
required.
-
Status LEDs are
off.
The relay switching duration was set. The system is in normal mode.
NOTICE
You can only set the relay switching duration for relay 2 on the
ekey
home CP mini 2
.
Setting the
relay
switching
duration