Ekars ERM-2640 Operating Manual Download Page 6

6

1. ZONE SELECTOR / G1-4 ALL switch - Control switch with LED indicator.

    (G1 ALL=GROUP-1, G2 ALL=GROUP-2, G3 ALL=GROUP-3, G4 ALL=GROUP-4 switches)

    Each of "G1-4 ALL" switch handle to "ON" status relating to definite each group switch array.

    It is not related to each of switch's on or off status when forced on status by specific

    G1-4 ALL switch but return to preset status when release the specific G1-4 ALL switch.

2. ZONE SELECTOR / GROUP-1~4 channel switch - Control switch with LED indicator.

    (GROUP-1 ~ GROUP-4 = x16,  16 channel selector switches per group)

    Each channel switching circuit supports individual switching point between channel out

    and combined "C" terminal and one to one correspondence of specific channel out 

    terminal block on rear panel.

          : Please do not apply and switch any high voltage or high current.

            All of the switching circuit nominal capacity is up to 48VDC/0.1A into resistive load.

          : Please released(push-OFF) all of "ZONE SELECTOR" section switches, after use them.

            If not, sometimes interrupted the PA system main program signal when those switches

            are maintain "ON" position.

Front Panel II

5

Front Panel I

6. MIC / ON switch - Control switch with LED indicator.

    This switch controls to attached gooseneck mic on or off.

    The internal monitor speaker volume will be -20dB reduced to preventing self acoustical

    feedback problem when activate this switch.

7. CHIME Level - CHIME signal output level control.

    Please fixed level refer to bargraph LED VU(below than 0dB, when the chime signal

    make peak value)or destination speakers chime SPL. 4-Notes chime sound is useful

    for pre announcement. It is not necessary to make big sound volume.

8. LM and HM EQUALIZER - Low MId(500Hz) and High MId(5KHz)band equalizer.

    The mid band equalizer can easily make clear sound against absorbing or reflecting

    energy from sound field. Center flat point and +/-12dB adjustable peaking resonance

    type equalizer.

9. MIC Gain Control - Mic headamp boost gain control

    This potentiometer can cover level of entire microphone sensitivity.

    The maximized boost gain is up to +60dB(CW), m10dB(CCW) that continually

    controlled end to end point. Please make the boost gain of attached gooseneck

    microphone refer to bargraph LED indicating status. Normally, can find ideal point of 

    boost gain b30dB and +50dB scale of mic gain potentiometer.

10. PHANTOM POWER SWITCH

    This switch turns on/off the phantom power supply.

    Use this switch when you are using condenser microphone. 

    When this switch is turned on, DC +18V will be supplied to pins 2 and 3 of 

 

MIC input jack.

    If you do not need phantom power supply for use dynamic microphone, 

    be sure to leave this turned off.

 

11. MIC input connector - XLR jack or 1/4" Phone jack acceptable.

    Please find enclosed gooseneck microphone and properly couple with this connector.

    Enclosed microphone that has uni directional acoustic axis characteristics should

    made on axis and maintained adequate distance 50 to 100mm between mic head

    assembly and mouth.

+18V

Summary of Contents for ERM-2640

Page 1: ...Eup Hwaseong City Kyunggi Do Korea 445 922 Tel 82 31 432 5112 82 31 432 4422 Fax 82 31 352 7637 82 31 352 7649 E mail export ekars co kr trade ekars co kr Home Page http www ekars co kr http www samhyoung co kr Headquarter Overseas Dep MEMO PUBLIC ADDRESS TOTAL SOLUTION ERM 2640 Public Address Remote Amplifier OPERATING MANUAL 18V ...

Page 2: ...5 Rear Panel 7 6 Specifications 8 SamHyoung Electronics Co Ltd 936 4 Kumuncheoun Ri Hyangnam Eup Hwaseong City Kyunggi Do Korea 445 922 Tel 82 31 432 5112 82 31 432 4422 Fax 82 31 352 7637 82 31 352 7649 Home Page http www ekars co kr http www samhyoung co kr E mail export ekars co kr trade ekars co kr ...

Page 3: ...g and that no objects filled with liquids such as vases shall be placed on the apparatus Unpacking And Installation CAUTION CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICICE PERSONNEL TO PREVENT FIRE OR SHOCK HAZARD WAR...

Page 4: ...s per group Built in electric balanced circuit for avoid ground loop problems High accurate 4 step LED VU to trace program signal output Heavy duty outer case Specifications 8 Mic headamp Maximum Gain 60dB Signal to noise ratio More than 60dB Gv 60dB 150 ohm terminated BW 20Hz to 20KHz Frequency response 80Hz to 18KHz 3dB Gv 40dB THD Less than 0 1 Gv 60dB 1KHz Equalizer Low middle F0 500Hz Peaking...

Page 5: ...POWER red color LED is indicating when enclosed external 24VDC 2A DC adapter working properly All electrical function will be ready within 2 second causing start initialize circuit Should be reset turned off all of ZONE SELECTOR switch before acting power switch on or off to avoid any audible pop noise via connected extra PA equipment 2 4 dot Bargraph LED VU Meter Displaying audio signal output le...

Page 6: ...al output level control Please fixed level refer to bargraph LED VU below than 0dB when the chime signal make peak value or destination speakers chime SPL 4 Notes chime sound is useful for pre announcement It is not necessary to make big sound volume 8 LM and HM EQUALIZER Low MId 500Hz and High MId 5KHz band equalizer The mid band equalizer can easily make clear sound against absorbing or reflecti...