![EK R3 User Manual Download Page 15](http://html1.mh-extra.com/html/ek/r3/r3_user-manual_2373568015.webp)
FUNCTIONS and OPERATION
POWER ON/OFF
The fixture is powered on by connecting the included power cable to mains
power (100 - 240 VAC, 50/60 Hz). Upon receiving power, the fixture will cycle
through a motor reset program. To power off, disconnect the power cable or
turn off power remotely using a switch.
MENU NAVIGATION
The control panel features five-button navigation of the onboard menu.
If the panel is password-protected, go to the Advanced menu, in the Menu
locking submenu, enter the Unlock code using the navigation buttons:
1234
Increase the
displayed
value, or
scroll thru
previous
menu items
Decrease the
displayed
value, or
scroll thru
next menu
items
Confirm displayed
values, or activate
displayed functions,
or enter submenus
UP
DOWN
ENTER
ENTER
LEFT
RIGHT
Return to
higher
menu levels
Advance
displayed unit
values by
10x and 100x
6
SET UP MENU
DMX ADDRESS : Set starting address value
DMX CHANNEL : Select 16- or 20-channel mode
OPTION MENU
PAN / TILT : Set values for: • Invert Pan
•
Invert
Tilt
•
Swap
Pan-Tilt
•
Encoder
Pan-Tilt
•
Pan/Tilt
Homing
Mode
• Pan Home Default Position
• Tilt Home Default Position
•
Pan/Tilt
Enable
DISPLAY : Set display behavior (on/off)
FAN MODE : Select Auto or Silent fan mode
SPECIAL FUNCTIONS :
• Pan/Tilt speed: Select Normal or Fast
• Dimmer curve: Select one of four dimmer curves
• RGB Gamma: Select desired gamma setting
• PWM Frequency: Select frequency to avoid camera flicker
SETTING : Load parameter presets for :
• Factory defaults
•
User
presets
1
•
User
presets
2
•
User
presets
3
INFORMATION MENU
Displays stored data and values for: • System errors
•
Fixture
operating
hours
•
LED
hours
•
System
firmware
versions
•
DMX
monitor
•
Fans
monitor
•
Unique
RDM
identifier
MANUAL CONTROL
RESET : Force fixture to reset
CHANNEL : Set output for each DMX channel
15