ITS Partner O.B.S S.L · Av. Cerdanyola 79-81 Local C
08172 Sant Cugat del Vallés · Barcelona (Spain)
Phone: +34935839543 · [email protected] · www.ek.plus
CM 8SH CI-TC
USER MANUAL
Program pool:
In this table all channels, services, which correspond to the selected entries will be listed. From here the
services that are wished to be assigned to each MUX output can be selected. Each service is assigned
to the input tuner from which it has been tuned.
S.I.D.: S.I.D. (Service Information Descriptor) assigned at source to that service.
Service name: name assigned to the service at source. Next, a symbol appears indicating whether the
service is TV or Radio, and whether it is encrypted or open.
DECODIFIC.: This module is provided with two slots to insert two CAMs. By clicking on it, we activate or
not the service so that it decodes in the selected CAM.
.MODULATION: each circle corresponds to a MUX output: 1, 2, 3 or 4. By clicking on that circle, it changes
from red to green, and this service is assigned to a MUX output.
DVB-T output card:
This part of the menu consists of three differentiated sections:
•
N.I.T. (Network Information Table) parameters
•
RF output channel parameters
•
Information window on the throughput of each MUX output
N.I.T. parameters:
•
Vers.: N.I.T. version
•
O.N.I.D.: Original Network Identification Descriptor.
•
N.I.D.: Network Identification Descriptor.
•
L.C.N.: Logical Channel Number. LCN type selection (EACEM for Europe, ITC for the United
Kingdom
…)
•
Network Name: identifies the name of the local DTT (Digital Terrestrial Television) network.
RF output channel parameters:
•
Freq. (KHz): Center frequency, in KHz, of the desired output channel. E.g. CH21=474000
•
Id. T.S.: T.S. identifier, in general, it is not necessary to change the identifier.
•
Const.: Constellation. Select the desired output constellation: 64QAM, 16QAM, QPSK.
•
Band: Output channel bandwidth: 7MHz or 8MHz.
•
F.E.C.: (Forward Error Correction). Select the error correction level: 7/8, 5/6, 3/4, 2/3, 1/2.
•
Guard Int. Select guard interval: 1/32, 1/16, 1/8, 1/4.
•
Atten. Level: The power level of the modulator is 95dBuV; it can be adjusted 20dB by using
this attenuator.