- 8 -

CONNECTING THE PUMP-S

The EK-D5 PWM pump has two connectors.

1.  4-pin Molex:

 It must be connected directly to your PSU at all 

times as it is used to power the pump.

2.  4-pin PWM fan:

 It can be connected to your motherboard’s CPU 

Fan or designated water pump header. It can also be connected to 
a controller. This cable is used to control and report the rotational 
speed of the pump. If it’s not connected, the pump will run at 
maximum speed (100% PWM).

4-pin molex 

connector

To make sure the installation of EK components was successful, we 
recommend you perform a leak test for 24 hours.

When your loop is complete and filled with coolant, connect the 
pump to a PSU outside of your system. Do not connect power to 
any of the other components. Turn on the PSU and let the pump 
run continuously. It is normal for the coolant level to drop during this 
process as air collects in the distribution plate.

Inspect all parts of the loop, and in the eventuality that coolant leaks, 
fix the issue and repeat the testing process. Ensure that all hardware is 
dry before the system is powered on in order to prevent any damage.

4-pin PWM fan 

connector

TESTING THE LOOP

Summary of Contents for Reflection 1000D

Page 1: ...USER GUIDE DISTRIBUTION PLATE EK Quantum Reflection 1000D ...

Page 2: ...ith the installation process The EK Fittings require only a small amount of force to screw them firmly in place since the liquid seal is ensured by the rubber O ring gaskets The use of corrosion inhibiting coolants is always recommended for any liquid cooling system EKWB recommends any of the EKCryofuel for worry free usage ...

Page 3: ...TING BRACKETS 4 ATTACHING THE DISTRIBUTION PLATE ON THE MOUNTING BRACKETS 5 RECOMMENDED DISTRIBUTION PLATE CONFIGURATIONS 6 CONNECTING THE D RGB LED STRIP 7 CONNECTING THE PUMP S 8 TESTING THE LOOP 8 SUPPORT AND SERVICE 9 SOCIAL MEDIA 9 ...

Page 4: ...ch the mounting brackets on PC case using M3 X 6 DIN7380 Screws and M3 nuts ATTACHING MOUNTING BRACKETS M3 x 6 DIN7380 M3 Nut M3 x 6 DIN7380 M3 x 6 DIN7380 M3 Nut LOWER MOUNTING BRACKET UPPER MOUNTING BRACKET ...

Page 5: ...closed M4 X 8 DIN7984 screws and steel washers ATTACHING THE DISTRIBUTION PLATE ON THE MOUNTING BRACKETS STEP 2 STEP 2 LOWER MOUNTING BRACKET Attach the EK Quantum Reflection 1000D D5 distribution plate on the Lower mounting bracket and secure it with enclosed M4 X 8 7984DIN Screws and steel washers Steel Washer M4 x 8 DIN7984 Steel Washer M4 x 8 DIN7984 ...

Page 6: ...L VRM OUTLET OPTIONAL RADIATOR 2 INLET WITH VRM RADIATOR 2 OUTLET RADIATOR 2 INLET WITHOUT VRM GPU OUTLET One must be used GPU OUTLET Using CPU2 OR GPU2 One must be used CPU 2 OR GPU 2 INLET OPTIONAL CPU 2 OR GPU 2 OUTLET USING CPU2 AND GPU2 DRAIN VRM INLET OPTIONAL RADIATOR 1 INLET RADIATOR 1 OUTLET With VRM RADIATOR 1 OUTLET Without VRM GPU INLET Onemustbeused CPU 2 OR GPU 2 INLET USING CPU2 AND...

Page 7: ...cated on the connector is pluggedintothe 5Vlineasindicatedonyourmotherboard If you put LED Diode to the 12V RGB HEADER you can damage the LEDs Connector is the same on D RGB and RGB versions but D RGB version has 3 cables from connector to PCB RGB version has 4 cables If you connect D RGB led to ordinary RGB header you can damage your motherboard or LED strip D RGB Header RGB Header CONNECTING THE...

Page 8: ...make sure the installation of EK components was successful we recommend you perform a leak test for 24 hours When your loop is complete and filled with coolant connect the pump to a PSU outside of your system Do not connect power to any of the other components Turn on the PSU and let the pump run continuously It is normal for the coolant level to drop during this process as air collects in the dis...

Page 9: ...or assistance please contact http support ekwb com EKWB d o o Pod lipami 18 1218 Komenda Slovenia EU EKWaterBlocks EKWaterBlocks ekwaterblocks ekwaterblocks EKWBofficial SUPPORT AND SERVICE SOCIAL MEDIA ...

Reviews: