background image

- 8 -

M4 x 62 SCREW 

D5 COVER

PUMP 

CABLES

ATTACHING THE PUMP COVER

STEP 1

Insert the pump cables through D5 Pump cover and place the cover 
over D5 pump. Make sure that holes are aligned. Secure the D5 
Pump cover using M4 x 62 mm screws and 2.5 mm Allen Key. Do not 
use excessive force while tightening the screws!

STEP 1

STEP 2

INSTALLING THE MOLEX  CONNECTOR

1. Put the screwdriver into pin gap in Molex connector
2. Recover flattered pin into original position
3. Put cables back to Molex connector and fan connector(Watch out 

for correct order of cables)

STEP 2

1. PUT THE 

SCREWDRIVER 
INTO PIN GAP 

2. RECOVER THE PINS

ORIGINAL 
POSITION

WATCH OUT FOR CORRECT 
ORDER OF CABLES

Summary of Contents for 3831109844090

Page 1: ...USER GUIDE EK Quantum Convection D5 ...

Page 2: ...t notice Please visit our website at www ekwb com for updates Before installation of this product please read important notice disclosure and warranty conditions printed on the back of the box Beforeyoustartusingthisproduct pleasefollowthesebasicguidelines Carefully read the manual before beginning the installation process The use of quality market proven corrosion inhibiting coolants is always st...

Page 3: ... 3 TABLE OF CONTENTS BOX CONTENTS 4 REQUIRED TOOLS 4 D5 COVER DIMENSIONS 5 MAIN PARTS 6 PREPARING THE PUMP 7 ATTACHING THE PUMP COVER 8 SUPPORT AND SERVICE 9 SOCIAL MEDIA 9 ...

Page 4: ... 4 Screw M4x62 4 pcs 62 mm BOX CONTENTS D5 Pump cover 1 pc Mounting Mechanism You may not need all the screws mounting mechanism is universal Allen Key 2 5 mm REQUIRED TOOLS ...

Page 5: ... 5 D5 COVER DIMENSIONS 71 mm 71 mm 56 mm ...

Page 6: ...ion EAN Description Quantity 1 100663 EK Badge 1 2 103312 D5 Cover Screw M4x62 Black Chrome 4 103313 D5 Cover Screw M4x62 Nickel 3 103314 D5 pump Cover Black 1 103315 D5 pump cover Nickel 103571 D5 pump Cover Silver 1 3 2 ...

Page 7: ...ver STEP 2 UNINSTALLING MOLEX CONNECTOR 4 PIN MOLEX CONNECTOR 1 Flatten the pins in Molex connector 2 Remove Cables from Molex connector 3 PIN FAN CONNECTOR 1 Push the pin on fan connector with screwdriver 2 Remove the cable ORIGINAL SCREW PUMP HOLDER 1 FLATTEN THE PINS 1 PUSH THE PIN STEP 1 4 PIN MOLEX CONNECTOR 3 PIN FAN CONNECTOR 2 REMOVE CABLES 2 REMOVE CABLES ...

Page 8: ...and 2 5 mm Allen Key Do not use excessive force while tightening the screws STEP 1 STEP 2 INSTALLING THE MOLEX CONNECTOR 1 Put the screwdriver into pin gap in Molex connector 2 Recover flattered pin into original position 3 Put cables back to Molex connector and fan connector Watch out for correct order of cables STEP 2 1 PUT THE SCREWDRIVER INTO PIN GAP 2 RECOVER THE PINS ORIGINAL POSITION WATCH ...

Page 9: ...rs refer to the page with MAIN PARTS where you can find the EAN number of each part you might need Include the EAN number with quantity in your request Mounting Mechanism EAN can be found under BOX CONTENTS Thermal pads are readily available in the EK shop EKWaterBlocks EKWaterBlocks ekwaterblocks ekwaterblocks EKWBofficial SUPPORT AND SERVICE SOCIAL MEDIA ...