background image

5

PRECAUTIONS

 WARNING

Use the enclosed AC adapter.

The enclosed AC adapter (AHM250PS48T) is for use with this product only. Do not use the AC adapter with 
other equipment. Do not use an AC adapter designed for other devices with this product.

Connecting to power sources that do not match the power ratings of the AC adapter may result in fire or 

electric shock.

To disconnect the power cord or adapter power cable, grasp the 

plug firmly and pull.

Tugging on the cord or cable may damage it and result in fire or electric 

shock.

To avoid the risk of electric shock, this equipment must only be connected to a 

supply mains with protective earth.

Use the correct voltage.

 •

The unit is designed for use with a specific voltage only. Connection to a voltage other than that specified in this 

“Instructions for Use” may cause fire, electric shock, or equipment damage.

 

Power supply: 100-240Vac 50/60Hz

 •

Do not overload your power circuit, as this may result in fire or electric shock.

Handle the power cord and AC adapter with care.

Handle the power cord and AC adapter with care.
Do not place heavy objects on the power cord or AC adapter, or pull or tie the power 

cord. Using a damaged cord or AC adapter may result in fire or electric shock.

The operator should not touch the patient while touching the product.

This product has not been designed to be touched by patients.

Never touch the plug, AC adapter or power cord during a thunderstorm.

Touching them may result in electric shock.

Do not touch a damaged LCD panel directly with bare hands.

Liquid crystal is poisonous. If any part of your skin comes in direct contact with the 

panel, wash thoroughly. If liquid crystal enters your eyes or mouth, immediately flush 

with large amounts of water and seek medical attention.

Summary of Contents for CuratOR EX4342

Page 1: ...tion Manual separate volume carefully to familiarize yourself with safe and effective usage For monitor adjustment and settings refer to the Installation Manual The Installation Manual is part of the...

Page 2: ...the region to which it was originally shipped If operated outside this region the product may not perform as stated in the specifications No part of this manual may be reproduced stored in a retrieval...

Page 3: ...nitor s power on Direct current Dangerous voltage CAUTION Refer to SAFETY SYMBOLS page 2 Protective earth grounding terminal Potential equalization terminal WEEE marking Product must be disposed of se...

Page 4: ...t correctly on a sufficiently sturdy desk or wall If the unit is installed incorrectly it may drop or fall over resulting in personal injury or equipment damage If the unit falls disconnect the power...

Page 5: ...this Instructions for Use may cause fire electric shock or equipment damage Power supply 100 240Vac 50 60Hz Do not overload your power circuit as this may result in fire or electric shock Handle the...

Page 6: ...or equipment damage Do not touch the plug or AC adapter with wet hands Doing so may result in electrical shock Use an easily accessible power outlet This is to facilitate disconnecting the power in ca...

Page 7: ...ng the unit while it is plugged into a power outlet may result in electric shock If you plan to leave the unit unused for an extended period of time disconnect the power plug from the wall socket afte...

Page 8: ...ly available medical devices commonly used in a medical environment The monitor cannot be used for direct diagnosis and as main device for monitoring live support equipment Intended users The intended...

Page 9: ...y Although missing pixels or lit pixels may appear on the LCD panel this is not a malfunction Percentage of effective dots 99 99 or higher Do not press on the panel or edge of the frame strongly as th...

Page 10: ...0 2 Benzalkonium chloride Alkylamine Incidin Plus 8 by vol Guanidine derivatives Lysoformin 2 by vol Quaternary compounds Incidur spray undiluted Mikrozid Sensitive Liquid undiluted Surfa safe ANIOS...

Page 11: ...on 16 2 1 Before Installing the Product 16 Installation Requirements 16 2 2 Installing the Product 17 2 3 Connecting the Power Cord 18 2 4 Connecting the Cables 19 2 5 Installing the Cable Cover 20 2...

Page 12: ...atible with UHD Other functions Optimal preset setting DisplayPort sRGB DisplayPort BT 2020 HDMI BT 2020 SDI BT 2020 Dual screen display PbyP and PinP Permits parallel display of two input images Equi...

Page 13: ...0PS48T Cable cover with screws Monitor attachment screw M8 14 x 4 User Manual CD Instructions for Use Installation Manual Outline Dimensions Safety Precautions 1 3 Controls and Functions AC adapter 2...

Page 14: ...input select menu 3 MENU button Displays the main menu 4 F1 Left button Executes the function assigned to this button Select items in the menu screen 5 F2 Right button 6 F3 Down button 7 F4 Up button...

Page 15: ...ill come into contact with a patient 14 RS 232C terminal D Sub 9pin Controls this product by connecting it to an external device Input switching and various adjustments are possible from connected ext...

Page 16: ...ough operational testing of the system cables arms etc in the environment where the product will be used Installation Requirements When installing the monitor ensure that there is adequate space aroun...

Page 17: ...ectly the attached part may be damaged which may result in injury or equipment damage When using an arm or stand attach it to achieve the following tilt angles of the monitor Up 45 down 45 Connect the...

Page 18: ...rminal on the monitor Align the connector shape with the port shape rotate the lock ring clockwise and fix it securely Note If the lock ring is stiff and does not rotate push it further into the monit...

Page 19: ...bles Do not connect or disconnect the signal cable while the monitor is turned on The SDI terminal DVI D terminal DisplayPort terminal and HDMI terminal are vulnerable to static electricity therefore...

Page 20: ...ween the cable cover and the monitor Securely tighten the screws in the two locations Screw tightening torque 0 4 N m to 0 7 N m Avoid subjecting the terminal and cable to stress Do not pack or transp...

Page 21: ...though the monitor is functioning properly This message appears when no signal is input Example The message shown on the left may appear because some devices to be connected do not output the signal i...

Page 22: ...NC 12G 6G 3G HD SDI DVI DVI D 1 Single link HDCP unsupported DisplayPort 1 HDCP unsupported Monitor Control Monitor Control Terminals RS 232C D Sub 9 pin x 1 Power Input DC 48 V 10 3 0 A Maximum Power...

Page 23: ...ns W H D 223 0 mm 37 0 mm 88 5 mm Net Weight Approx 1 1 kg Operating Environmental Requirements Temperature 0 C to 35 C 32 F to 95 F Humidity 20 to 85 R H no condensation Air Pressure 540 hPa to 1060...

Page 24: ...essive 60 000 P P P P 1920 1080 Progressive 59 940 P P P P 1920 1080 Interlace 60 000 P P P 1920 1080 Interlace 59 940 P P P 720 480 Progressive 60 000 P 1 P 1 720 480 Progressive 59 940 P 1 P 1 720 5...

Page 25: ...lectromagnetic waves that could influence limit or result in malfunction of the monitor Install the equipment in a controlled environment in which such effects are avoided Classification of Equipment...

Page 26: ...hould not be used adjacent to or stacked with other equipment If adjacent or stacked use is necessary the equipment or system should be observed to check for normal operation in the configuration in w...

Page 27: ...nce level Electromagnetic environment Guidance Electrostatic dis charge ESD IEC EN61000 4 2 8 kV contact discharge 2 4 8 15 kV air dis charge 8 kV contact discharge 2 4 8 15 kV air dis charge Floors s...

Page 28: ...ould be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol Note 1 UT is the a c mains voltage prior to applic...

Page 29: ...LAN 802 11 a n Pulse modulation b 217 Hz 0 2 0 3 9 9 5500 5785 a For some services only the uplink frequencies are included b Carrier waves are modulated using a 50 duty cycle square wave signal The E...

Page 30: ...nce when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction man...

Page 31: ...PBDE SJ T 11364 GB T 26572 GB T 26572 Repairs Please contact the sales partner from whom you purchased the product with the serial number of the product The serial number is the 8 digit number displa...

Page 32: ...Copyright 2022 EIZO GmbH All rights reserved 1st Edition February 2022 CuratOR EX4342 Instructions for Use 1086011 001 Carl Benz Stra e 3 76761 R lzheim Germany...

Reviews: