Measured noise value 

The A-valued machine’s noise level typically is:: 
Nois pressure level = 87 dB (A).    Noise power level = 100 dB (A). 

Measured vibration value 

The valued acceleration typically is 7 m/s² 

Usage 

This angle grinder can be used for separating and grinding many different materials, e.g. 
metal or stone. In case of doubt please read the manufacturer’s instructions. Do not use this 

Mains connection 

Connect only to a single-phase AC current supply and only to the mains voltage specified on 
the rating plate. Connection to sockets without earth protection is possible as the appliance 
features protective insulation to DIN 57740/VDE 0740 and CEE 20. Radio suppression com-
plies with the Europe an standard EN 55014. W hen fitting the plug, make sure that the brown 
(live) wire of this appliance is connected to the plug terminal marked L or coloured red, and 
the blue (neutral) wire of this appliance is connected to the plug terminal marked N or col-
oured black. Under no circumstances must the wires of this appliance be connected to the 
earth terminal of the plug marked either E, with the earth symbol, or coloured green or 
green/yellow . 

Smooth start 

The electronic smooth start will prolong the life of both the motor and the gears. 

Switching on and off 

Switching on: Push the sliding switch forward. To lock, depress the front part of the switch. 
Switching off: To unlock, depress the back part of the sliding switch. The switch will automati-
cally move back to "0". 

Electronic 

The number of revs is adjusted electronically when the load increases.  
In case of a longer overload period the speed is decreased electronically. The machine contin-
ues to run slowly to cool down the motor coil. After switching off and on the machine can be 
used at rated load. The duration of cooling-down period depends on the gra de of overload.   

Speed selection (A G 1300-125 XE) 

Spee d pre-selection with the setting wheel: 
A = lowest speed 

G = highest speed 

Mounting the protective cover 
 

Open the clamping lever. Push the protective cover over the gear neck, if necessary slightly 
loosen the nut of the tension screw. 

Fitting the working tool 

Always disconnect the plug from the socket before carrying out any work on the machine. 

Maintenance 

Keep the machine and the ventilation slots clean.  
Only use Original accessories and spare parts. Should components which have not been de-
scribed need to be exchanged please contact one of our Atlas Copco service agents. 

Service agents 

Worldwide service by Atlas Copco. The corresponding addresses are to be found in the at-
tached brochur e. 

Protective cap with clamping lever 

Align the protective cap as required and fasten the clamping lever. If the protective cap is not 
tight enough, open the clamping lever, slightly fasten the nut of the tension screw and re-
fasten the clamping lever. 

The protective cap must no t be movable when the clamping  lever is locked. Take 
care that the g rind ing disk can be f reely tu rned.

 

Technical data 

1.520 Watt, 220 – 240 V, 50 – 60 Hz. Continuous speed control by speedo ge nerator 
(constant number of revs). Weight approx. 2,4 kg. 

FIXTEC-quick-action adjusting  nut 
Customary adjusting  nut 

Lock the work spindle by depressing the spindle lock. Mount the tension flange, the working 
tool, and the adjusting nut as shown in illustration. 
Only tighten and loosen the 

FIXTEC

 quick-action adjusting nut by hand. 

Do not u se any 

tools!

 Insure that the hoop of the FIXTEC quick-action adjusting nut is only placed in the 

upward position for tightening/looseni ng. Loosen respectively tighten the adjusting nut with a 
pin-type face spanner 

Guarantee 

A 12 month guarantee (as from invoice date) is given for all technical and mechanical parts, 
except in the case of outside culpability. 

Spares can be sup plied accord ing to  the list. We will carry ou t necessary repairs.

 