REPAIRS 

 

 

1. 

Should  an  electrical  component  fail,  consult  the  Factory  Service 
Center to obtain the proper replacement part. 

 

 

 

2. 

If refrigerant gas is lost from the machine, it will be necessary to use 
a  refrigeration  technician  to  correct  the  fault.    Contact  the  Factory 
Service Center prior to initiating this action.  

 

 

 

Any  competent  refrigeration  technician  will  be  able  to  service  the 
equipment.  The following procedure must be used: 

 
 

 

a.  The source of the leak must be determined and corrected. 

 
 

 

b.  The  machine  should  be  thoroughly  evacuated  before 

recharging. 

 

 

 

 

c.  The  unit  must  be  recharged  with  refrigerant  measured 

accurately by weight. 

 
 

 

d.  For evacuation and recharging of the machine, use the crimped 

and brazed charging stub attached to the side of the refrigerant 
compressor. 

 

 

 

 

The  charging  stub  should  be  crimped  and  rebrazed  after 
servicing.  

N

EVER

 

allow permanent service valves to be fitted to 

any part of the circuit.  Service valves may leak causing further 
loss of refrigerant gas. 

 

 

 

3. 

The  refrigerant  compressor  fitted  to  the  dehumidifier  is  a  durable 
unit that should give many years of service.  Compressor failure can 
result from the machine losing its refrigerant gas.  The compressor 
can be replaced by a competent refrigeration technician.   

 
 

 

Failure  of  the  compressor  can  be  confirmed  by  the  following 
procedure: 

 
 

 

a.  Establish  that  power  is  present  at  the  compressor  terminals 

using a voltmeter. 

 

 

 

b.  With the power disconnected, check the continuity of the internal 

winding  by  using  meter  across  the  compressor  terminals.    An 
open circuit indicates that the compressor should be replaced. 

 

 

 

c.  Check that the compressor is not grounded by establishing that 

a  circuit  does  not  exist  between  the  compressor  terminals  and 
the shell of the compressor.  

Summary of Contents for LD-82

Page 1: ...11 16 LD LD LD LD 82 82 82 82 DEHUMIDIFIER PROCESS DEHUMIDIFIER PROCESS DEHUMIDIFIER PROCESS DEHUMIDIFIER PROCESS DRYER DRYER DRYER DRYER 1320500 1320500 1320500 1320500 OWNER S MANUAL OWNER S MANUAL...

Page 2: ...it is simple to install and operate The process dryer is energy efficient quiet to operate and will cause no pollution problems The Ebac method of drying is a process of dehumidification The LD 82 deh...

Page 3: ...moisture which is collected and led away The cool air then passes the hot condenser where it is reheated with the same energy removed during the cooling phase With the addition of other radiated heat...

Page 4: ...anufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained in this unit please refer to the product data label MODEL LD 82 HEIGHT 600...

Page 5: ...on the outside of the chamber or adjacent wall WIRING Connect the LD 82 dehumidifier process dryer to a 230V 1 phase 50Hz supply as follows Brown Live Blue Neutral Green Yellow Earth ground DRAINAGE...

Page 6: ...of the fan motor is to run continuously whenever power is supplied to the dehumidifier The fan motors used in the LD 82 dehumidifier process dryer unit are induction protected i e the motor is able to...

Page 7: ...e the build up of ice No attempt should be made to cut open any part of the refrigeration circuit due to high pressures and gas involved If the unit is switched off at the mains power supply for any r...

Page 8: ...using and that it rotates freely The motor is sealed for life and therefore does not require lubrication 3 To check the refrigerant charge run the unit for 15 20 minutes and briefly remove the cover T...

Page 9: ...he refrigerant compressor The charging stub should be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak causing...

Page 10: ...ressor OH Protector 3021529 Compressor Start Relay 3021530 Compressor Start Capacitor 3021531 Condenser Coil 3020740 Evaporator Coil 2320515 Filter Dryer 3020937 Fan Motor 3040214 Heater Element Prote...

Page 11: ...d This product contains fluorinated greenhouse gases covered by the Kyoto Protocol The refrigeration system is hermetically sealed The Global Warming Potential GWP of refrigerants used in products man...

Page 12: ...ww eipl co uk sales eipl co uk American Sales Office Ebac Industrial Products Inc 700 Thimble Shoals Blvd Suite 109 Newport News Virginia 23606 2575 USA Tel 01 757 873 6800 Fax 01 757 873 3632 www eba...

Reviews: