Page 2 of 12 

Drawing   : - TPC148 
Issue 

: - 4 

Date 

: - 24/11/16 

 
 

UNPACKING 

 

Carefully  remove  the  PP6  dehumidifier  unit  from  its  transit  box  and  visually 
check  for  signs  of  transit  damage.  If  there  is  evidence  of  damage  DO  NOT 
attempt  to  operate  the  unit,  call  your  supplier  for  advice.  Do  not  discard  the 
packing; it will be useful when transporting the dehumidifier unit in the future. 

 

INTRODUCTION 
 

Dehumidifiers remove moisture from the air that is circulating through the unit. 
The  resulting  reduction  of  relative  humidity  helps  prevent  rust,  rot,  mould, 
mildew  and  condensation  within  the  room,  or  other  enclosed  spaces  where 
the dehumidifier is used. 
A  dehumidifier  consists  of  a  motor-compressor  unit,  a  refrigerant condenser, 
an  air  circulating  fan,  a  refrigerated  surface,  a  means  of  collecting  and 
disposing the condensed moisture and a cabinet to house these components. 
The fan draws air through the refrigerated surface and cools it below its dew 
point,  removing  moisture  which  is  collected  and  led  away.  The  cool  air  then 
passes  the  hot  condenser,  where  it  is  reheated.  With  the  addition  of  other 
radiated heat the air is discharged into the room at a higher temperature but 
lower  relative  humidity  than  when  the  air  entered  the  unit.  Continuous 
circulation of the room air through the dehumidifier unit gradually reduces the 
relative humidity in the room. 
 
 

 

The  PP6  dehumidifier  is  a  robust,  compact  unit  designed  to  control  the 
humidity in the enclosed space in which it is placed. 

 

The  unit  is  thermally  protected  and  will  switch  off  for  a  period  if  the 
maximum operating temperature of 50ºC is exceeded. 

 

The  PP6  has  been  designed  for  the  exacting  conditions,  which  can 
prevail  in  the  medium  to  long  term  storage  of  mobile  shelters  and 
vehicles. It combines lightness and compactness with high reliability and 
strength. 

 

Handles contribute to its portability. 

 

The gas which is used inside the hermetically sealed refrigeration circuit 
is  R134a  which  contains  no  CFC`s  and  has  therefore  a  zero  ozone 
depletion factor. But under no circumstances should this gas be released 
into  the  atmosphere,  the  unit  should  be  serviced  by  trained  personnel 
who will reclaim any of the unwanted gas. 

 

A stowage plate (part no. 1012305) is available to provide secure fixing 
for the PP6 dehumidifier unit under transport conditions. 

Summary of Contents for Ebac PP6

Page 1: ...Page 1 of 12 Drawing TPC148 Issue 4 Date 24 11 16 PP6 DEHUMIDIFIER OWNER S MANUAL www eipl co uk ...

Page 2: ...s reheated With the addition of other radiated heat the air is discharged into the room at a higher temperature but lower relative humidity than when the air entered the unit Continuous circulation of the room air through the dehumidifier unit gradually reduces the relative humidity in the room The PP6 dehumidifier is a robust compact unit designed to control the humidity in the enclosed space in ...

Page 3: ...ng Potential GWP of refrigerants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained in this unit please refer to the product data label MODEL PP6 HEIGHT 256mm WIDTH 300mm DEPTH 470mm WEIGHT 25 Kg AIRFLOW 7 M3 min POWER SUPPLY 230V 1 ph 50Hz POWER 350W max FINISH Epoxy coated Zintec steel REFRIGERANT TYPE QT...

Page 4: ...allation and operation the unit inlet and outlet must have a clearance of 0 5M from all adjacent surfaces and or structures WIRING Connect the power mains cable to a 5 or 13 Amp power supply As follows Brown Live Blue Neutral Green Yellow Earth ground DRAINAGE Connect a 12 5mm inside diameter hose to the condensate outlet pipe positioned centrally beneath the air inlet grille Secure the hose using...

Page 5: ...TION If the ambient temperature of the room in which the dehumidifier unit is conditioning falls below 15ºC ice will form on the evaporator coil as the air is passed over it after a time this build up of ice on the evaporator coil will effect the efficiency of the unit on its ability to maintain the required set conditions for the room The PP6 is therefore fitted with a defrost control device This...

Page 6: ...ve the build up of ice No attempt should be made to cut open any part of the refrigeration circuit due to high pressures and gas involved If the unit is switched off at the mains power supply for any reason the unit must be allowed to stand at rest for at least three minutes before restarting Failure to do so may cause the unit to blow the fuses owing to the compressor due to there being a refrige...

Page 7: ...ve 25 C the coil may be covered with droplets of water rather than frost Partial frosting accompanied by frosting of the thin capillary tubes indicates loss of refrigerant gas or low charge 4 Check all wiring connections 5 To check the operation of the defrost system switch the machine on and leave it running for approximately 45 minutes The machine will then enter Hot Gas defrost mode for approxi...

Page 8: ...the refrigerant compressor The charging stub should be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak causing further loss of refrigerant gas 3 The refrigerant compressor fitted to the dehumidifier is a durable unit that should give many years of service Compressor failure can result from the machine losing ...

Page 9: ...e the fan motor 3 See Routine Maintenance Section 4 Check the wiring diagram to find fault and repair 5 Adjust humidistat as required or replace Little or no water extraction 1 Insufficient air flow 2 Compressor fault 3 Loss of refrigerant gas 1 Check all of the above 2 Contact the Factory Service Center 3 Contact the Factory Service Center Little or no defrost when required 1 Faulty Timer 2 Fault...

Page 10: ...over 3021518 Condenser Coil 3020740 Evaporator Coil 3014203 Filter Dryer 3020937 Fan Motor 3030194 Fan Blade 3040101 By pass Valve 3020811 P C B Timer 1601900 Solenoid Coil 3030422 Drain Tube 3014338 Worm Drive Clip 3086101 Clip Nut 3080501 Mains Cable 3031225 Control Humidistat 3031528 Stowage Plate 1012305 Fastener 3087401 Washer 3087403 Spare parts available online www EIPLDIRECT com ...

Page 11: ...rd This product contains fluorinated greenhouse gases covered by the Kyoto Protocol The refrigeration system is hermetically sealed The Global Warming Potential GWP of refrigerants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained in this unit please refer to the product data label Due to the high pressure...

Page 12: ...www eipl co uk sales eipl co uk American Sales Office Ebac Industrial Products Inc 700 Thimble Shoals Blvd Suite 109 Newport News Virginia 23606 2575 USA Tel 01 757 873 6800 Fax 01 757 873 3632 www ebacusa com sales ebacusa com German Sales Office Ebac Industrial Products Ltd Gartenfelder Str 29 37 Gebäude 35 D 13599 Berlin Germany Tel 49 3043 557241 Fax 49 3043 557240 www eip ltd de sales eip ltd...