background image

 

 

 

 

Page 1 of 16 

Drawing   : - TPC252 
Issue 

: - 6 

Date 

: - 10/12/13 

 
 
 
 
 
 
 

CD425 (1018110)

 

INDUSTRIAL DEHUMIDIFIER 

OWNER’S MANUAL 

 
 

 

 
 
 
 
 
 
 
 
 

www.eipl.co.uk  

Summary of Contents for 1018110

Page 1: ...Page 1 of 16 Drawing TPC252 Issue 6 Date 10 12 13 CD425 1018110 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www eipl co uk ...

Page 2: ...Page 2 of 16 Drawing TPC252 Issue 6 Date 10 12 13 CD425 PACKAGE CONTENTS Item Description Quantity 1018110 Dehumidifier 1 3086119 Jubilee clip 2 3014315 Reinforced tubing 16mm I D 2 X 3M TPC252 Manual 1 ...

Page 3: ...Page 3 of 16 Drawing TPC252 Issue 6 Date 10 12 13 ...

Page 4: ...in tray for collecting and disposing of condensed moisture f A cabinet to house the above components The fan draws the moist air through the evaporator coils which cools the air below its dew point Moisture forms on the evaporator and is collected in the condensate tray which leads away to a permanent drain The cooled air then passes through the hot condenser where it is reheated using the same en...

Page 5: ...rigerants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained in this unit please refer to the product data label MODEL CD425 HEIGHT 1193 mm 47 WIDTH 1092 mm 43 DEPTH 482 mm 19 WEIGHT 160 kg 353 lbs AIRFLOW 1750 CFM 2975M3 Hr TOTAL POWER 3680 MAX MAXIMUM OPERATING TEMPERATURE 35ºC 95ºF POWER SUPPLY 220V 3PH ...

Page 6: ...rocess a Remove the front cover b Check the actual relative humidity inside the area c Set humidity control to a LOWER value than the actual relative humidity d After approximately 6 minutes check the compressor is running e Leave the machine to run for 15 minutes NOTE ensure that the set humidity see c above is set very low as the compressor will switch off when the actual RH coincides with the s...

Page 7: ...nd flooding of the chamber WIRING Connect a suitably fused 3 phase mains power supply to the MAINS T B terminal block inside the electrical box located at the control panel end of the machine DRAINAGE Connect the outlet from the drain tray located behind the front grille and under the evaporator coils to a permanent drain Please ensure that the drainage does not rise above the level of the CD425 s...

Page 8: ...emperatures above 25 C the coil may be covered with droplets of water rather than frost Partial frosting accompanied by frosting of the thin capillary tubes indicates loss of refrigerant gas or low charge 4 Check all wiring connections 5 To check the operation of the defrost system ensure the air temperature is below 20 ºC switch the machine on and leave it running for approximately 1 hour The mac...

Page 9: ...the refrigerant compressor The charging stub should be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak causing further loss of refrigerant gas 3 The refrigerant compressor fitted to the dehumidifier is a durable unit that should give many years of service Compressor failure can result from the machine losing ...

Page 10: ...ng diagram to find fault and repair Little or no water extraction 1 Insufficient air movement 2 Compressor fault 3 Loss of refrigerant gas 4 Blocked filter dryer 1 Check all of the above 2 Contact the Factory Service Center 3 Contact the Factory Service Center 4 Contact the Factory Service Center Unit vibrates excessively 1 Loose compressor 2 Damaged fan 1 Tighten the nuts on the compressor mounts...

Page 11: ...r Dryer 3020930 1 Capillary Tube 3014251 12 X 1400mm X 0 047 R407c Freon Refrigerant 3100451 2 5kg Drain Tube 2014315 3 meters 3 8 Copper Tube 3014203 2 meters 1 2 Copper Tube 3014204 2 meters 5 8 Copper Tube 3014205 2 meters Cork Tape 3100223 1 2 Roll Fan Motor 3030140 1 Axial Fan 3010119 1 Solenoid Coil 3030402 1 Humidistat 1132200 1 Momentary Switch 3030634 1 Indicator Lamp Holder 3034513 2 12V...

Page 12: ... 6 Date 10 12 13 Spare parts available online ww EIPLDIRECT com Humidistat Control Knob 2017707 1 Contactor 037H0021 3030355 1 Contactor 037H0041 3030362 1 Relay 3030270 1 Overload 3032646 1 Transformer 3031129 1 Defrost Timer 1619400 1 ...

Page 13: ... WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THE FOREGOING DESCRIBED MERCHANDISE For Your Records Model ____________________ S N ______________________ Date Received ______________ SAVE THIS SECTION FOR YOUR RECORDS CLIP AND RETURN THIS CARD PLEASE NOTE WARRANTY REGISTRATION To ensure that your Ebac Dehumidifier is accorded the full coverage provided by this warranty please complete and mail this ...

Page 14: ...Page 14 of 16 Drawing TPC252 Issue 6 Date 10 12 13 ...

Page 15: ...Page 15 of 16 Drawing TPC252 Issue 6 Date 10 12 13 ...

Page 16: ...www eipl co uk sales eipl co uk American Sales Office Ebac Industrial Products Inc 700 Thimble Shoals Blvd Suite 109 Newport News Virginia 23606 2575 USA Tel 01 757 873 6800 Fax 01 757 873 3632 www ebacusa com sales ebacusa com German Sales Office Ebac Industrial Products Ltd Gartenfelder Str 29 37 Gebäude 35 D 13599 Berlin Germany Tel 49 3043 557241 Fax 49 3043 557240 www eip ltd de sales eip ltd...

Reviews: