10. Possible causes of failure
Problem
Cause
Solution
The compressor
does not start
1. No supply voltage
2. Insu
ffi
cient supply voltage
3. Outside temperature is too low
4. Motor is overheated
1. Check the supply voltage, the pow-
er plug and the socket-outlet.
2. Make sure that the extension cable
is not too long. Use an extension
cable with large enough wires.
3. Never operate with an outside tem-
perature of below +5°C.
4. Allow the motor to cool down If
necessary, remedy the cause of the
overheating.
The compressor
starts but there is no
pressure
1. Leak in the non-return valve
2. The seals are damaged.
3. The drainage screw for
condensation water (11) leaks.
1. Replace the non-return valve
2. Check the seals and have any da-
maged seals replaced by a service
center
3. Tighten the screw by hand. Check
the seal on the screw and replace if
necessary.
The compressor
starts, pressure is
shown on the pres-
sure gauge, but the
tools do not start.
1. Loose hose connections
2. Leak in a quick-lock coupling
3. Insu
ffi
cient pressure set on the
pressure regulator.
1. Check the compressed air hose
and tools and replace if necessary.
2. Check the quick-lock coupling and
replace if necessary.
3. Open the pressure regulator further.
Anl_TH_AC_190_6_SPK8.indb 26
Anl_TH_AC_190_6_SPK8.indb 26
05.05.15 09:21
05.05.15 09:21
Summary of Contents for TH-AC 190/6 OF
Page 41: ...41 Anl_TH_AC_190_6_SPK8 indb 41 Anl_TH_AC_190_6_SPK8 indb 41 05 05 15 09 21 05 05 15 09 21...
Page 42: ...42 Anl_TH_AC_190_6_SPK8 indb 42 Anl_TH_AC_190_6_SPK8 indb 42 05 05 15 09 21 05 05 15 09 21...
Page 43: ...43 Anl_TH_AC_190_6_SPK8 indb 43 Anl_TH_AC_190_6_SPK8 indb 43 05 05 15 09 21 05 05 15 09 21...