GB
- 30 -
8.6 Cleaning the intake
fi
lter (1)
The intake
fi
lter prevents dust and dirt being
drawn in. It is essential to clean this
fi
lter after at
least every 300 hours in operation. A clogged
intake
fi
lter will decrease the compressor‘s per-
formance dramatically. Undo the screw on the
air
fi
lter so that the halves of the air
fi
lter housing
can be opened. Use compressed air at low pres-
sure (approx. 3 bar) to blow out all the parts of
the
fi
lter and then assemble the
fi
lter in reverse
order. When cleaning, take adequate precautions
against dust (e.g. use a suitable face mask).
8.7 Storage
Warning!
Pull the mains plug out of the socket and ventilate
the appliance and all connected pneumatic tools.
Switch o
ff
the compressor and make sure that it is
secured in such a way that it cannot be started up
again by any unauthorized person.
Important!
Store the compressor only in a dry location.
Always store upright, never tilted!
9. Disposal and recycling
The equipment is supplied in packaging to pre-
vent it from being damaged in transit. The raw
materials in this packaging can be reused or
recycled. The equipment and its accessories are
made of various types of material, such as metal
and plastic. Never place defective equipment in
your household refuse. The equipment should
be taken to a suitable collection center for proper
disposal. If you do not know the whereabouts of
such a collection point, you should ask in your
local council o
ffi
ces.