CV) It is prohibited to use any type of HSS saw
blade and cutting-off wheel.
To use the equipment properly you must also
observe the safety information, the assembly
instructions and the operating instructions to be
found in this manual.
All persons who use and service the equipment
have to be acquainted with these operating
instructions and must be informed about the
equipment‘s potential hazards. It is also
imperative to observe the accident prevention
regulations in force in your area. The same
applies for the general rules of health and
safety at work. The manufacturer will not be
liable for any changes made to the equipment
nor for any damage
resulting from such changes. Even when the
equipment is used as prescribed it is still
impossible to eliminate certain residual risk
factors. The following hazards may arise in
connecti
on with the machine‘s construction and
design:
•
Contact with the saw blade in the uncovered
saw zone.
•
Reaching into the running saw blade (cut
injuries).
•
Kick-back of workpieces and parts of
workpieces.
•
Saw blade fracturing.
•
Catapulting of faulty carbide tips from the
saw blade.
•
Damage to hearing if essential ear-muffs are
not used.
•
Harmful emissions of wood dust when used
in closed rooms.
4. Technical data
Mains voltage: ..........................230-240V ~
50Hz Power: .........................500 W S1, 800 W
S6 15% Idle speed n
0
: .......................................
2950 rpm Carbide saw blade: .........Ø 200 x Ø 16
x
2.4
mm
Maximum
tooth
pitch
............................... 2.4 mm Number of teeth:
............................................
24
Table
size:
.....................................505 x 373 mm Max.
cutting height: ......................... 45 mm / 90°
........................................................ 27 mm / 45°
Dust extraction connector: ....................Ø 36 mm
Weight: ....................................... approx. 11.6
kg Thickness of the splitter: ......................... 2.2
mm
Operating mode S6 15%: Continuous operation
with idling (cycle time 10 minutes). To ensure
that the motor does not become excessively hot,
it may only be operated for 15% of the cycle at
the specifi ed rating and must then be allowed to
idle for 85% of the cycle.
Danger!
Noise
The noise emission values were measured in
accordance with EN 62841.
Operation
L
pA
sound pressure level ..................... 87.2
dB(A) K
pA
uncertainty ........................................
3 dB(A) L
WA
sound power level .....................
100.2 dB(A) K
WA
uncertainty
........................................ 3 dB(A)
Wear ear-muff s.
The impact of noise can cause damage to
hearing.
The stated noise emission values were
measured in accordance with a set of
standardized criteria and can be used to
compare one power tool with another.
The stated noise emission values can also be
used to make an initial assessment of exposure.
Warning:
The noise emission levels may vary from the
level specifi ed during actual use, depending on
the
- 21 -
Summary of Contents for TC-TS 200
Page 6: ...Anl_TC_TS_200_SPK9 indb 6 13 11 2019 12 55 51 6 14b 15 16 17 18 3...
Page 17: ...Anl_TC_TS_200_SPK9 indb 17 13 11 2019 12 55 55 D 15...
Page 33: ...Anl_TC_TS_200_SPK9 indb 33 13 11 2019 12 55 58 GB 28...
Page 48: ...F Anl_TC_TS_200_SPK9 indb 48 13 11 2019 12 56 01 41...
Page 59: ...Anl_TC_TS_200_SPK9 indb 59 13 11 2019 12 56 02 I 50...
Page 83: ...Anl_TC_TS_200_SPK9 indb 83 13 11 2019 12 56 05 S 70...
Page 94: ...CZ Anl_TC_TS_200_SPK9 indb 94 13 11 2019 12 56 06 80...
Page 108: ...SK Anl_TC_TS_200_SPK9 indb 108 13 11 2019 12 56 08 92...
Page 123: ...E Anl_TC_TS_200_SPK9 indb 123 13 11 2019 12 56 10 105...
Page 134: ...E Anl_TC_TS_200_SPK9 indb 134 13 11 2019 12 56 11 115...
Page 156: ...SLO Anl_TC_TS_200_SPK9 indb 156 13 11 2019 12 56 13 134...
Page 169: ...Anl_TC_TS_200_SPK9 indb 169 13 11 2019 12 56 14 H 146...
Page 172: ...Anl_TC_TS_200_SPK9 indb 172 13 11 2019 12 56 14 148...
Page 173: ...Anl_TC_TS_200_SPK9 indb 173 149 13 11 2019 12 56 15...
Page 174: ...Anl_TC_TS_200_SPK9 indb 174 EH 11 2019 01 13 11 2019 12 56 15...