CAUTION!
Read all safety regulations and instructions.
Any errors made in following the safety regulations
and instructions may result in an electric shock, fire
and/or serious injury.
Keep all safety regulations and instructions in a
safe place for future use.
2. Layout (Fig. 1-5)
1 Tank
indicator
2 Tank
cover
3
2 x 230 V~ socket-outlets
4 Earth
connection
5 Overload
cut-out
6 Voltmeter
7
Oil filler plug
8
Oil drain plug
9
Oil shortage cut-out
10 On/Off switch
11 Choke lever
12 Reversing starter
13 Petrol cock
14 Wheels
15 Axle
16 Foot
17 Push bar holder
18 Push bar
19 Screws size M8 x 40
20 Screws size M8 x 16
21 Washers for wheels
22 Securing split pins for wheels
23 Nuts M8
3. Proper use
The device is designed for applications operated with
a 230 V alternating current source. Be sure to
observe the restrictions in the safety instructions.
The generator is intended to provide electric tools
and light sources with electricity.
When using the device with household appliances,
please check their suitability in accordance with the
relevant manufacturer’s instructions. In case of
doubt, ask an authorized dealer of the respective
appliance.
The machine is to be used only for its prescribed
purpose. Any other use is deemed to be a case of
misuse. The user / operator and not the
manufacturer will be liable for any damage or injuries
of any kind caused as a result of this.
Please note that our equipment has not been
designed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
4. Technical data
See warranty card of your country.
5. Before putting the machine into
operation
5.1 Assembly
앬
Assemble the foot, wheels and push bar as
shown in Figures 6-8.
앬
Assemble all parts before filling in fuel and oil in
order to prevent the fluids from leaking out.
앬
To mount the wheels, first slide the axle through
the mountings on the bottom of the generator
and fit the wheels as shown on Figure 7. Make
sure that the sides of the wheels with the more
protruding wheel hubs are facing towards the
generator, as the wheels will otherwise drag
against the frame.
5.2 Electrical safety:
앬
Electric supply cables and connected equipment
must be in perfect condition.
앬
The generator is to be operated only with
equipment whose voltage specifications conform
with the generator's output voltage.
앬
Never connect the generator to the power supply
(socket-outlet).
앬
Keep the cable length to the consumer as short
as possible.
5.3 Environmental protection
앬
Dispose of soiled maintenance material and
operating materials at the appropriate collection
point.
앬
Recycle packaging material, metal and plastics.
5.4 Connecting to earth
The housing is allowed to be connected to earth in
order to discharge static electricity. To do this,
connect one end of a cable to the earth connection
on the generator (Fig. 3) and the other end to an
external earth (for example an earthing rod).
GB
13