11. Troubleshooting guide
Fault
Possible causes
Remedy
Motor does not start - Safety plug is not inserted
- Battery is not correctly inserted
- Motor terminals or capacitor dis-
connected
- Excessive working depth
- Battery empty
- Insert the safety plug (see 6.)
- Remove the battery and reinsert
(see 5.)
- By customer service workshop
- Reduce the working depth
- Charge the battery (see 5.)
Motor performance
drops
- Soil too hard
- Blades badly worn
- Correct working depth
- Replace hoe blades
Notice! For protection, the motor is equipped with a thermal switch which cuts out when the
motor is overloaded and switches on again automatically after a short cooling period.