11. Troubleshooting guide
Faults
Cause
Remedy
The equipment
does not start
- Battery is not correctly inserted
- Remove battery and insert again
The equipment
does not pump
- Intake sieve clogged
- Discharge hose kinked
- Clean intake sieve with water jet
- Unkink the hose
Insu
ffi
cient pumping
rate
- Intake sieve clogged
- Performance reduced due to heavi-
ly contaminated and abrasive water
impurities
- Battery performance decreasing
- Clean intake sieve
- Clean equipment and replace wear
parts
- Check the battery performance and
charge the battery if necessary
The equipment swit-
ches o
ff
after brie
fl
y
running
- Motor circuit-breaker switches the
equipment o
ff
due to excessive wa-
ter contamination
- Water temperature too high; motor
circuit-breaker switches the equip-
ment o
ff
- Take out the battery and clean the
equipment and the shaft.
- Ensure that maximum permissible
water temperature (35 °C) is not
exceeded