4. Technical data
Power supply (rechargeable battery) .... 18 V d.c.
Max. operating pressure
(compressor compressed air) ............... 10,5 bar
Theoretical suction rate
(compressor compressed air) ......... 21 liters/min
Output for compressed air at 4 bar ........... 9 l/min
Output for compressed air at 7 bar ........... 6 l/min
Max. volumetric
fl
ow for suctioning
(low-pressure blower): .......................... 370 l/min
Max. volumetric
fl
ow for in
fl
ating
(low-pressure blower): .......................... 390 l/min
Compressor idling speed ................... 3450 min
-1
Blower idling speed .......................... 15000 min
-1
Weight without battery ................. approx. 1.8 kg
Protection type ............................................ IP X0
Length of compressed air hose .... approx. 71 cm
Length of air hose ........................ approx. 31 cm
Danger!
Sound and vibration
The noise emission values were measured in ac-
cordance with EN ISO 3744.
L
pA
sound pressure level ..................... 71.5 dB(A)
K
pA
uncertainty .............................................3 dB
L
WA
sound power level ....................... 82.5 dB(A)
K
WA
uncertainty .............................................3 dB
Wear ear-mu
ff
s.
The impact of noise can cause damage to hea-
ring.
Keep the noise emissions and vibrations to a
minimum.
•
Only use appliances which are in perfect wor-
king order.
•
Service and clean the appliance regularly.
•
Adapt your working style to suit the appliance.
•
Do not overload the appliance.
•
Have the appliance serviced whenever ne-
cessary.
•
Switch the appliance off when it is not in use.
Caution!
Residual risks
Even if you use this electric power tool in
accordance with instructions, certain resi-
dual risks cannot be rules out. The following
hazards may arise in connection with the
equipment’s construction and layout:
•
Damage to hearing if no suitable ear protec-
tion is used.
Danger!
The electric power tool generates an electro-
magnetic
fi
eld during operation. Under certain
circumstances this
fi
eld may actively or passively
impede medical implants. To reduce the risk of
serious or fatal injuries, we recommend persons
with medical implants to consult their doctor and
the manufacturer of the medical implant prior to
using the equipment.
5. Before using the equipment
Before you connect the equipment to the power
supply make sure that the data on the rating pla-
te are identical to the data for the rechargeable
battery.
•
Check the equipment for damage which may
have occurred in transit. Report any damage
immediately to the transport company which
was used to deliver the compressor.
•
Make sure that the intake air is dry and dust-
free.
•
Do not install the compressor in a damp or
wet room.
•
The compressor may only be used in suitable
rooms (with good ventilation and an ambient
temperature from +5 °C to 40 °C). There must