-27-
Electrical Adjustments
[Adjustment Condition]
●
Input signal
Video signal ........................ 1.0Vp-p/75
W
terminated, 16 steps gray scale
(Composite video signal)
Component Video signal ...... 1.0Vp-p/75
W
terminated, 8 color 100% color
bar or 16 step gray scale (Component video
signal)
Computer signal ................... 0.7Vp-p/75
W
terminated, 16 steps gray scale
pattern
●
Image control mode ......... “STANDARD” mode unless otherwise noted.
Note:
* Please refer to “Service Adjustment Menu Operation” for entering the service mode and adjusting the service data.
White 100%
Black 100%
Circuit Adjustments
CAUTION: The each circuit has been made by the fine adjustment at factory. Do not attempt to adjust the following
adjustments except requiring the readjustments in servicing otherwise it may cause loss of performance
and product safety. Before adjustment, please turn on the projector more than ten minutes.
16 steps gray scale pattern
After replacing the Power Board readjust the Output volt-
age adjustment as follows.
1. Connect a digital voltmeter to pins 1 (+) and 2 (-) of
K6A
.
2. Adjust the voltage by using VR601 as following.
AC Input
Reading
230V
370V ±2V
Caution:
Be sure to connect the lamp when taking this adjustment.
* This adjustment is not required even if the power board
is replaced because this adjustment is carried out be-
fore parts shipment.
Output Voltage adjustment
WArNING : uSe uV rAdIAtION eYe ANd SKIN
PrOteCtION durING SerVICING.
CAutION:
to prevent suffer of uV radiation, those adjustments
must be completed within 25 minutes.
1. Enter the service mode.
2. Connect a digital voltmeter to test point “
tPFANA
” (+)
and chassis ground (-). Select group no. “
250
”, item
no. “
0
” and change data value to adjust voltage to be
5.0 ±0.1V
.
3. Connect a digital voltmeter to test point “
tPFANB
” (+)
and chassis ground (-). Select group no. “
250
”,item
no. “
2
” and change data value to adjust voltage to be
5.0 ±0.1V
.
4. Connect a digital voltmeter to test point “
tPFANC
” (+)
and chassis ground (-). Select group no. “
250
”,item
no. “
4
” and change data value to adjust voltage to be
5.0 ±0.1V
.
5. Connect a digital voltmeter to test point “
tPFANA
” (+)
and chassis ground (-). Select group no. “
250
”,item
no. “
1
” and change data value to adjust voltage to be
13.5 ±0.1V
.
6. Connect a digital voltmeter to test point “
tPFANB
” (+)
and chassis ground (-). Select group no. “
250
”,item
no. “
3
” and change data value to adjust voltage to be
13.5 ±0.1V
.
7. Connect a digital voltmeter to test point “
tPFANC
” (+)
and chassis ground (-). Select group no. “
250
”,item
no. “
5
” and change data value to adjust voltage to be
13.5 ±0.1V
.
z
Fan Control adjustment
Summary of Contents for LC-XB42
Page 61: ...61 IC Block Diagrams FA7701 DDC Control IC5751 AN5870 Signal Switch IC5201...
Page 62: ...62 IC Block Diagrams FA7711 DC DC Converter IC5801 FA5502 P F Control IC601...
Page 65: ...65 IC Block Diagrams LM4889 Audio Output IC5031 NJW1156 Audio Control IC5001...
Page 66: ...66 IC Block Diagrams PW190 Scaler IC301 STR Z2156 Power OSC IC651...
Page 67: ...67 IC Block Diagrams TE7783 Parallel I O Expander IC1802...
Page 95: ......
Page 96: ...KG3BC April 2008 Japan 2008 Eiki Internatinal Inc A key to better communications...