EK-620U/EK-621W
4-2
4-3 Factory Reset
After final QC step, we have to erase all saved
change again and restore the OSD default setting.
The following actions will allow you to erase all
end-users’ settings and restore the default setting:
- Please get into service mode
- Select "Factory Reset"
- Press "Enter"
2.Service mode
Item
Label
Description
1
Factory Reset
Restore all settings to their default value,It will not reset network
2
Filter Wheel Index
Adjust the R/G/B value to get perfect image when image loss some kinds of color
3
Phosphor Wheel Index
Adjust the R/G/B value to get perfect image when image loss some kinds of color
4
Error Log
Record the times of the failure of power on of projector
5
Mode Adjustment
Image adjustment of vertical and horizontal position
6
Reset Projector Hours
Reset Projector Hours
7
Light Sensor Calibration Choose this function to execute ABC calibration
8
ADC Calibration
Choose this function to execute ADC calibration
9
LD Hours