OXYVET IV OXYGEN CONCENTRATOR 

T +49 7461 96 580 0 | F +49 7461 96 580 90 | [email protected] | www.eickemeyer.com

CONTENT

1.  Important Safeguards .............................................................................................................. 4
2. Introduction .............................................................................................................................. 5
3.  How your Oxyvet IV Oxygen Concentrator works  ................................................................ 5
4.  Important Parts of your Concentrator .................................................................................... 5

Front View (Figure 1) .............................................................................................................................6
Back View (Figure 2)  .............................................................................................................................7

5.  Setting up your Oxygen Concentrator ................................................................................... 7
6.  Before Operating your Oxygen Concentrator ........................................................................ 8
7.  Operating your OxyVet IV Oxygen Concentrator .................................................................. 9
8.  Reserve Oxygen System ........................................................................................................10
9.  Caring and periodic Maintenance for your Unit ..................................................................10

Oxygen Humidifi er (reusable Bottles) 

 ......................................................................................... 10

Cannula, Mask and Tubing

 ................................................................................................................ 10

Air Filter and Oxygen Outlet Connector

 ...................................................................................... 10

Exterior Cabinet

 ................................................................................................................................... 11

Periodic Maintenance for your Unit .............................................................................................. 11

10.  Minor Troubleshooting ..........................................................................................................12

11.  Specifi cations

 ..........................................................................................................................13

12. Symbol ....................................................................................................................................14
13.  Electromagnetic Immunity ....................................................................................................15

Summary of Contents for 213180

Page 1: ...USER MANUAL OXYVET IV OXYGEN CONCENTRATOR Item no 213180 Version 1 04 2020 TELEPHONE 49 7461 96 580 0 www eickemeyer com ...

Page 2: ...2 USER MANUAL OXYVET IV OXYGEN CONCENTRATOR T 49 7461 96 580 0 F 49 7461 96 580 90 export eickemeyer com www eickemeyer com ...

Page 3: ...ack View Figure 2 7 5 Setting up your Oxygen Concentrator 7 6 Before Operating your Oxygen Concentrator 8 7 Operating your OxyVet IV Oxygen Concentrator 9 8 Reserve Oxygen System 10 9 Caring and periodic Maintenance for your Unit 10 Oxygen Humidifier reusable Bottles 10 Cannula Mask and Tubing 10 Air Filter and Oxygen Outlet Connector 10 Exterior Cabinet 11 Periodic Maintenance for your Unit 11 10 ...

Page 4: ...dous Seeking medical advice before using an oxygen concentrator is advisable 1 IMPORTANT SAFEGUARDS Read this entire guide before using your OxyVet IV Oxygen Concentrator Important information are highlighted by these terms throughout this guide Danger Urgent safety information for hazards that will cause serious injury or death Warning Important safety information for hazards that might cause ser...

Page 5: ...near a person utilizing oxygen therapy Do not use within 5 feet 1 6 m of hot sparking objects or naked sources of flame 3 HOW YOUR OXYVET IV OXYGEN CONCENTRATOR WORKS Oxygen concentrators are the most reliable efficient and convenient source of supplemental oxygen available today the oxygen concentrator is electrically operated The unit separates oxygen from room air which allows high purity supplem...

Page 6: ...ectrical overload shutdown 3 Humidifier Holder 4 Oxygen outlet oxygen is dispersed through this port 5 Flow meter 6 Flow meter knob 7 Monitor indicate the condition of oxygen purity status and hour meter 8 Green Power light illuminates when your concentrator is operating 9 Normal Oxygen green light the LED display normal oxygen optional 10 Low Oxygen yellow light the LED display low oxygen optional...

Page 7: ...on your unit near an electrical outlet in the room where you spend most of your time Danger Keep the oxygen concentrator at least 5 feet 1 6 m from hot sparking objects or naked sources of flame Note Do not connect to an electrical outlet controlled by a wall switch NO other appliances should be plugged into the wall outlet 2 Position your unit at least 6 inches 16 cm from walls draperies or any ot...

Page 8: ...ysician has prescribed an oxygen humidifier as part of therapy follow these steps a Fill the humidifier bottle with distilled water Do not overfill b Attach the oxygen tubing directly to the humidifier bottle outlet fitting Figure 4 Figure 4 Your physician has prescribed either a nasal cannula catheter or face mask in most cases they are already attached to the oxygen tubing If not follow the manufactu...

Page 9: ...ow rate Caution It is very important to follow your oxygen prescription Do not increase or decrease the flow of oxygen consult your physician Note EICKEMEYER may have preset the flow meter so that it can not be adjusted If the flow meter knob is turned clockwise the flow decreases and eventually will shut off the oxygen flow If the knob is turned counterclockwise the flow increases The OxyVet IV Oxygen ...

Page 10: ...ution of hot water and dishwashing detergent 2 Soak the humidifier in a solution of one part white vinegar to three parts hot water for 30 minutes This solution acts as a germicidal agent 3 Rinse thoroughly with warm tap water and refill with distilled water for use Do not overfill Cannula Mask and Tubing Clean and replace the cannula mask and tubing as instructed by EICKEMEYER Air Filter and Oxygen ...

Page 11: ...the Air Filter and Oxygen Outlet Connector 2 Change the felt of the Inlet Pre Filter at least once half a year Follow those steps Open the Important Safeguard pull out the Inlet Pre Filter Pull out the old felts from the Inlet Pre Filter two sides Then insert the new felts to the Inlet Pre Filter each side insert the Inlet Pre Filter and close the Important Safeguard 3 Change the Bacterial Filter ...

Page 12: ...ask or oxygen tubing Detach cannula catheter or face mask If proper flow is restored clean or replace if necessary Disconnect the oxygen tubing at the oxygen outlet If proper flow is restored check oxygen tubing for obstructions or kinks Replace if necessary Blocked or defective humidifier bottle Detach the humidifier from the oxygen outlet If proper flow is obtained clean or replace humidifier Flow met...

Page 13: ... Item Rating 1 Delivery Rate 0 5 to 5 LPM 2 Outlet Pressure 8 5 13 psi 68 5 90 kpa 3 Electrical Rating 230 V 50 Hz 1 4 A Max 4 Oxygen Percentage 0 5 5 LPM 93 3 5 Average oxygen concentration At 2 l min 93 3 6 Operating Environment Range Temperature 10 C to 40 C Humidity 15 to 95 Atmospheric pressure 50 106 kpa 7 3 15 4 psi 7 Weight 15 3 kg 8 Sound Level ISO 8359 1996 from front 55 dbA 9 Dimensions...

Page 14: ...ctive 2002 96 EC WEEE Directive after over the valid term within 3 years the machine should be treated on local law or regulation requirement To avoid hurt users and pollute environment The equipment bears CE mark indicating its conformity with the provision of Council Directive 93 42 EEC concerning medical devices FRAGILE Contents of the transport package are fragile therefore it shall be handled...

Page 15: ...d is the recommended separation distance in metres m b Field strengths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply...

Page 16: ... EICKEMEYER Sp z o o Al Jana Pawła II 27 00 867 Warszawa T 48 22 185 55 76 F 48 22 185 59 40 info eickemeyer pl www eickemeyer pl DENMARK EICKEMEYER ApS Solbakken 26 Hammelev 6500 Vojens T 45 7020 5019 info eickemeyer dk www eickemeyer dk NETHERLANDS EICKEMEYER B V Bellweg 44 4104 BJ Culemborg T 31 345 58 9400 info eickemeyer nl www eickemeyer nl ITALY EICKEMEYER S R L Via G Verdi 8 65015 Montesil...