Thermoelectric Air conditioner installation and 

operation manual  

 

FOR 1500 Btu MODEL #’S 

 

AAC-145-4XT-EP 

AAC-145-4XT-HC-EP 

AAC-145-4XT-NF-EP 

AAC-145-4XT-HC-NF-EP 

 
 
 

    

Cooling Solutions for 

Cooling Solutions for 

Cooling Solutions for 

Cooling Solutions for     

Mission

Mission

Mission

Mission----Critical Electronics

Critical Electronics

Critical Electronics

Critical Electronics

  

    

 

 

Summary of Contents for AAC-145-4XT-EP

Page 1: ...nditioner installation and operation manual FOR 1500 Btu MODEL S AAC 145 4XT EP AAC 145 4XT HC EP AAC 145 4XT NF EP AAC 145 4XT HC NF EP Cooling Solutions for Cooling Solutions for Cooling Solutions for Cooling Solutions for Mission Mission Mission Mission Critical Electronics Critical Electronics Critical Electronics Critical Electronics ...

Page 2: ...abinet The outside of the cabinet may be in outdoor atmosphere There is a barrier in the middle of the unit separating inside and outside sections The unit is intended to be permanently connected The unit meets the following standards ANSI ISA 12 12 01 2012 Nonincendive Electrical Equipment for Use in Class I and II Division 2 and Class III Division 1 and 2 Hazardous Classified Locations Dated 07 ...

Page 3: ...TALLING THE AIR CONDITIONER 7 INSTALL THE DRIP PAN 9 APPLY POWER 9 3 OPERATION 3 1 thermostat set points and heating cooling units 10 3 2 maintenance 10 EIC SOLUTIONS INC EIC SOLUTIONS INC EIC SOLUTIONS INC EIC SOLUTIONS INC 700 VETERANS WAY SUITE 200 WARMINSTER PA 18974 PHONE 1 215 443 5190 or 1 800 497 4524 FAX 215 443 9564 EMAIL info eicsolutions com VISIT US ON THE WEB AT www eicsolutions com ...

Page 4: ...ic Air Conditioner operates on this principle so there is no compressor and no expensive ozone depleting CFC s EIC s air conditioners use Thermoelectric modules sandwiched between high performance aluminum heat sinks high CFM axial fans and a patented electronic design to pump the heat from the inside of your enclosure to the outside without exposing your delicate electronics to any outside air or...

Page 5: ...irty environment 2 2 ORIENTATION Your AC unit can be mounted either vertically on the front rear or sides of your enclosure See Figure 2 1 Vertically mounted 1500 Btu units are always mounted with the exposed heatsink fins facing up and down never left and right Fig 2 1 Vertical installations often require the use of a Condensate Drip Pan part DP V depending on a number of factors including intern...

Page 6: ...ATION OF 1500 BTU UNIT WITH DP V VERTICAL DRIP PAN AND DRAIN TUBE HOT SIDE OF AC OUTSIDE OF ENCLOSURE COLD SIDE OF AC INSIDE OF ENCLOSURE DRAIN TUBE ENCLOSURE DP V DRIP PAN HOT SIDE FANS COLD SIDE FANS HOT SIDE HEAT SINKS COLD SIDE HEAT SINKS COLD SIDE HEAT SINKS HOT SIDE HEAT SINKS ...

Page 7: ...ied in the installation manual 4 Using a pencil center punch or other method mark the exact center point of each mounting hole on the enclosure Also mark the four corners of the section to be cut out 5 Using the jigsaw cut the opening in the enclosure 6 Using the 29 drill bit drill a hole at each of the marks you made earlier 7 Using the 8 32 tap tap each of the holes you have drilled 2 4 INSTALLI...

Page 8: ...8 8 8 8 1 800 497 4524 EIC SOLUTIONS INC 215 443 5190 Figure 2 2B Narrow Flange models only DO NOT use with standard models Figure 2 2A Standard Flange models only DO NOT use with Narrow Flange models ...

Page 9: ...LY POWER Once the air conditioner is mounted check the serial label and confirm the voltage required and then apply appropriate power as outlined below The unit is intended to be permanently connected Attach the wires to an appropriate power source using standard safe wiring methods Wire colors are as follows Black or Brown line White or Blue line neutral Green or Green Yellow ground A wiring diag...

Page 10: ...tually maintenance free The only time maintenance is required is when a unit is installed in an extremely dirty environment In these cases the hot side heat sinks outside the enclosure should be inspected regularly for a build up of dust or dirt If a build up is present on the heat sink fins it can be easily removed as follows 1 Disconnect the power from the unit 2 Dry dust dirt can be removed usi...