Strobe Light & Vibration Pad Module

Deaf & Hearing Impaired

RadioLINK Alarm System

For use with RF Smoke/Heat/CO Alarms

 

(Smoke / Heat / CO  Alarm

supplied separately)

Model Ei170RF

RadioLINK Alarm System with Strobe & Vibration Pad

Model Ei171RF

RadioLINK Alarm System with Strobe

(Only)

Note: At least one RF Smoke/CO/Heat Alarm is required to make the Ei170RF / Ei171RF 

Alarm operational. This is not supplied with the Ei170RF / Ei171RF and must be obtained 

separately.

Important: Read these instructions, together with those from the separate RF Smoke/CO/

Heat Alarms and accessories before installation. All instruction leaflets must be left with the 

end user after installation.

Models: Ei170RF

Ei171RF

Summary of Contents for RadioLINK Ei170RF

Page 1: ...LINK Alarm System with Strobe Only Note At least one RF Smoke CO Heat Alarm is required to make the Ei170RF Ei171RF Alarm operational This is not supplied with the Ei170RF Ei171RF and must be obtained separately Important Read these instructions together with those from the separate RF Smoke CO Heat Alarms and accessories before installation All instruction leaflets must be left with the end user ...

Page 2: ...s Note If installing the Ei170RF Ei171RF in a system containing CO Alarms we recommend installing an Ei450 to determine the source of the alarm 2 Installation Strobe Module Ei170RF Ei171RF The battery must first be installed in the Strobe Module Open the rear compartment by squeezing together the two latches as shown in Figure 1b and lifting the cover off Plug the battery into the socket at the re...

Page 3: ...screws accurately The screws large heads should be screwed into the wall leaving a gap of approximately 4mm 0 15in under the head Fit the keyhole slots on the back of the Strobe Module over the screw heads and slide the panel down vertically into position Battery Battery Plug Latch Figure 2 Battery Clearance Notch Figure 3 Shows battery orientation Dress the battery leads as shown replace the batt...

Page 4: ... code all other RF Alarms and devices in the system Consult the instruction manuals on how to house code the Alarms and devices It is essential that each individual Alarm device is put into House Code mode in its final location 3 Check the number of flashes on the Ei170RF Ei171RF and on every other device They should correspond to the total number of devices in your system A system with 3 Smoke Al...

Page 5: ...5 Mains Indicator Green mains disconnected amber flash 4 seconds RadioLINK Indicator Blue House Code Button Alarm Indicator Red Fault Indicator Amber Test Button Strobe TEST ALARM FAULT Figure 4 ...

Page 6: ...battery is almost depleted Both indicators will go off to indicate the battery is depleted and the unit is totally unpowered The battery will last 5 years in normal use provided it is not exposed to extremes of temperature for prolonged periods or fully discharged charged a large number of times We recommend that the functioning of the rechargeable battery is checked at least yearly as follows 4 2...

Page 7: ... is fully connected and that the connection is not damaged If the amber fault indicator flashes check that the battery is connected 6 Limitations of Radio Communications Ei Electronics radio communication systems are very reliable and are tested to high standards However due to their low transmitting power and limited range required by regulatory bodies there are some limitations to be considered ...

Page 8: ...rkmanship If this device should become defective within the guarantee period we shall at our discretion repair or replace the faulty unit This guarantee only applies to normal conditions of use and service and does not include damage resulting from accident neglect misuse unauthorised dismantling or contamination howsoever caused This guarantee excludes incidental and consequential damage Do not i...

Page 9: ...9 Template for Mounting Screws Drill Holes Here 12V 180mA max Aux1 12V 20mA max Aux2 Remove protection plug before connecting accessories Vibration Pad Ei170RF Conversion Jack Ei171RF Figure 5 ...

Page 10: ...5 sec 1 flash 5 sec 1 flash 5 sec 1 flash 5 sec off off off off off off off off Mains off battery connected Mains off battery virtually depleted Mains off battery fully depleted In Alarm Activated by an Alarm RF signal Test Mode Test button pressed 1 flash 2 sec 40 flashes min on for 4 sec on for 4 sec 2 sec on off pulse on 1 flash 2 sec Test button pressed on RF Alarm Fault Mode Vibration Pad dis...

Page 11: ...11 Mains Indicator Green mains disconnected amber flash 4 seconds RadioLINK Indicator Blue Control Panel Indicators Alarm Indicator Red Fault Indicator Amber Strobe TEST ALARM FAULT Indicator Summary ...

Page 12: ...ible harm to the environment or to human health When disposing of this product please separate it from other waste streams to ensure that it can be recycled in an environmentally sound manner For more details on collection and proper disposal please contact your local government office or the retailer where you purchased this product Block E1 Hereby Ei Electronics declares that this Ei170RF Ei171R...