11
8.
Replace the wiring cover.
9.
Carefully line up the unit on the base and slide on.
10.
Press the Test/Hush button for 10 seconds.The
horn will sound. Check that any interconnected
alarms also sound within this period.
11.
Connect the mains power to the alarm circuit.
Check the green light is on.
The CO Alarm is now fully operational and will
provide protection against a build up of Carbon
Monoxide gas 70 seconds after it is connected to
the mains supply.
12.
The unit may be tamperproofed further by
removing the knockout in the sidewall of the
mounting plate (as shown in
Figure 4
) and
inserting the self tapping screw (3mm diameter,
12mm long) after the unit is on the mounting
plate.
L N IC
(IF PRESENT)
EARTH
L - LIVE
N - NEUTRAL
IC - INTERCONNECT
TERMINAL SCREWS
RECESSED WIRING AREA
MAINS WIRING
L N IC
KNOCK OUT FOR
SURFACE WIRING
CONDUIT
WIRING
CONDUIT
INSERT SCREWDRIVER TO LIFT
AND REMOVE WIRE COVER
KNOCK OUT
FOR SURFACE WIRING
CONDUIT
SEALING GASKET
(MUST BE IN PLACE)
WIRING
CONDUIT
Figure 5 -
Surface Wiring
Figure 6 -
Recessed Wiring