We recommend a monthly check of your Alarm system.

When checking the system also check the Relay Base as follows:
1.  Check that the green LED power indicator is lit on the Alarm 

that is electrically connected to the Relay Base. If it is off, check 

the circuit breaker fuse, wiring, etc.. when the mains power is 

restored, the green LED will come on solid.

2.  Press the Alarm Test Button and check that:

 

a. The relay switches and 

 

b. The auxiliary device behaves as expected

End of Life

After 10 years (see date label on the side of the Relay Base) the 

Relay Base must be replaced.

It is important to check that the rechargeable cells in the Ei128RBU 

are switched on, charged and capable of switching the relay contacts. 

This should be done after installation and then at least annualy.

1. Disconnect the mains supply.

2. Check the relay as described in section 6.

3. If everything is satisfactory, re-connect the mains.

If the relay fails to operate, then the unit is defective and must be 

replaced (see section 8).

If, within the guarantee period, your Relay Base fails to work after 

your have carefully read all the instructions, checked that the unit 

has been installed correctly, and is receiving AC power, then 

contact us at the nearest address given at the end of this manual.  
If you are advised to return your Relay Base, please ensure that it 

is placed in a padded box, that the slide switch for the rechargeable 

cells is on the OFF position (Ei128RBU only) and include the proof 

of purchase and a note stating the nature of the fault.

Ei Electronics, guarantees the Relay Bases for five years from date 

of purchase against any defects that are due to faulty materials or 

workmanship. If this Relay Base should become defective within 

the guarantee period, we shall at our discretion repair or replace 

the faulty unit.
This guarantee only applies to normal conditions of use and 

service, and does not include damage resulting from accident, 

neglect, misuse, unauthorised dismantling, or contamination 

howsoever caused. This guarantee excludes incidental and 

consequential damage.
This guarantee does not apply to any product that has been 

modified in any way by a third party or has been fitted with a 

third-party element.
Do not interfere with the Relay Base or attempt to tamper with it.  

This will invalidate the guarantee, but more importantly may expose 

the user to shock or fire hazards. 
This guarantee is in addition to your statutory rights as a consumer.

7. Checking the Relay Back Up Cells (Ei128RBU)

8. Getting your Relay Base Serviced

9. Guarantee

6. Checking your Smoke Alarm System

Summary of Contents for Ei128R

Page 1: ...upply to boilers triggering panels etc The Relay Bases are powered by 230VAC mains with the Ei128RBU model having recharbeagle back up cells The Relay Bases are normally installed directly underneath an Easi fit Alarm base but can also be sited separately As supplied the relay operates continuously e g it switches when one of the Alarms sounds and switches back when it receives the alarm cancel si...

Page 2: ...NS TO TERMINAL BLOCK NO NC C VOLT FREE RELAY CONTACT FOR THE CONTROL OF THE AUXILIARY DEVICE C COMMON NC NORMALLY CLOSED NO NORMALLY OPEN DOUBLE INSULATE ALL WIRES VOLT FREE FOR THE C AUXILIARY C COMMO NC NORM NO NORM DOUBLE INS L N IC N IC L PILLARS C CONTINUOUS RELAY CHANGES UNTIL ACTIVATION STOPS Figure 1b Ei128RBU SURFACE CONDUIT CABLE ENTRY P PULSE RELAY CHANGES FOR 5 SECONDS C CONTINUOUS REL...

Page 3: ...ower source that utilises an inverter e g PV solar panel the Total Harmonic Distortion THD must be less than 5 If in doubt please check with the manufacturer of the inverter This also applies to battery powered UPS Uninterruptible Power Supply inverters The Relay Bases must not be powered from a light dimmer circuit WARNING First disconnect the mains from the circuit to be used WARNING To prevent ...

Page 4: ...r to prevent air draughts that could affect the performance of the Alarm to be sited on top 8 Remove the wiring cover on the Alarm mounting plate to view the terminal see fig 3a 9 Connectthethreewires L Live N NeutralandIC Interconnect from the Relay Base to the terminal on the Alarm s mounting plate The IC wire must be connected even if it is a single Alarm installation 9 Replace the wiring cover...

Page 5: ...rminal block Screw tightening torque max 0 5Nm 5 1kgf cm 4 Screw the Relay Base in place 5 3 Wiring the relay 1 Connect the L Live wire from the power supply of the auxiliary device to the C Common terminal 2 Then connect either the NC or NO contact of the relay depending on what is required for controlling the auxiliary device to the auxiliary device For example if the relay is used to cut out a ...

Page 6: ...wer 8 The green LED on the Alarm s should be on When the test button is pressed the horn should sound and the relay will switch within 10 seconds Note A maximum of 12 Alarms may be interconnected to one Relay Base When one Alarm sounds all interconnected Alarms will sound and the relay will switch Attention Do not interconnect Carbon Monoxide Alarms with Smoke Heat Alarms unless an Ei1529RC contro...

Page 7: ... power then contact us at the nearest address given at the end of this manual If you are advised to return your Relay Base please ensure that it is placed in a padded box that the slide switch for the rechargeable cells is on the OFF position Ei128RBU only and include the proof of purchase and a note stating the nature of the fault Ei Electronics guarantees the Relay Bases for five years from date...

Page 8: ...nics com The crossed out wheelie bin symbol that is on your product indicates that this product should not be disposed of via the normal household waste stream Proper disposal will prevent possible harm to the environment or to human health When disposing of this product please separate it from other waste streams to ensure that it can be recycled in an environmentally sound manner For more detail...

Reviews: