![Ei Electronics Ei100MRF Instructions Manual Download Page 19](http://html.mh-extra.com/html/ei-electronics/ei100mrf/ei100mrf_instructions-manual_2368825019.webp)
Supply Voltage:
9V from attached alarm
RF Range:
A minimum of 100 metres in free space
RF Visual Indicator:
Blue light flashes continuously for 0.5 to 3.5 seconds while
transmitting RF signal
RF Frequency:
868.499MHz (1% duty cycle)
Max RF Power:
+10dBm
Dimensions:
80mm length x 19mm depth x 16mm height
Temperature Range:
0° to 40°C
Humidity Range:
15% to 95% Relative Humidity
Interconnect *:
Up to 12 Ra or RadioLINK modules
Optional Accessories:
Ei407 Manual Call Point, Ei428 Relay Module ,Ei414 Fire /
CO Alarm Interface, Ei450 RadioLINK Alarm Controller
Approvals:
RF performance to EN 300 220-1 in accordance
with EN 300 220-2
EMC performance to EN 301 489-1 in accordance
with EN 301 489-3
*
We recommend, for ease of installation and RF communication, that up to 12 RF devices can be installed in
any one RF coded system. Please contact us for further advise if additional RF devices are required.