Ei Electronics Ei 405 Instruction Leaflet Download Page 8

8

If there are frequent nuisance/false alarms it may be neces-
sary to re-locate the device away from the source of the
fumes.

If you installed the smoke alarms as received and did not pro-
gram them, you may be receiving an alarm signal from a
neighbouring system. This can be easy rectified by  house
coding  your alarms (see section 6.3).

Pressing the test & hush button on the smoke alarm sensing
fire (i.e. with the red light flashing rapidly) will silence the
alarm for 10 minutes. (Pressing the hush button on the option-
al Ei 410 Remote Control acts in the same way).

5. INSTALLING YOUR SMOKE ALARMS

1. Select a location complying with the above advice.

2. Remove the mounting plate from the Smoke Alarm by
releasing the tamperproof catch with a small screwdriver as
shown in figure 1a and sliding the alarm from the mounting
plate.

3. Place the base on the ceiling/wall  exactly where you want
to mount the unit. With a pencil, mark the location of the two
screw holes.

4. Taking care to avoid any electrical wiring in the ceiling, drill
holes through the centres of the marked locations. Push the
plastic screw anchors provided into the drilled holes. Screw in
firmly.

5. Connect the battery to the battery snaps as shown in figure
1b (models Ei405  & Ei405C only). 

6. Carefully line up the unit on the base and slide on. (This
connects the batteries in the Ei 405C, TY, TYC units.

Install all the other alarms similarly.

6. LOOKING AFTER YOUR SMOKE ALARMS

6.1  

Manually Testing your Smoke Alarm

It is recommended that you test your Smoke Alarm at least
weekly to be sure the unit is working.  It will also help you and
your family to become familiar with the sound of the Alarm.

When you press the test button it
simulates the effect of smoke during
a real fire.  So, there is no need to
test the Alarm with smoke.

Press and hold the Test Button until
the alarm sounds (Figure 7).  The
alarm will stop sounding shortly
after the button is released.

Figure 7

Summary of Contents for Ei 405

Page 1: ...lar before renovations begin Ei Electronics 2003 P N B15026 R0 RADIO SMOKE ALARMS with WIRELESS INTERCONNECT INSTRUCTION LEAFLET Contains vital information on unit operation and installation Read and retain carefully If you are just installing the unit this leaflet MUST be given to the householder MODELS Ei 405 Replaceable 9V Battery Ei 405C Replaceable 9V Battery hard wired interconnect option Ei...

Page 2: ...TY Ei405TYC slide unit on to mounting plate to connect the batteries When the battery is first connected the Alarm may sound for 2 3 seconds and or the red light may flash quickly for 10 seconds this is normal A Smoke Alarm does not prevent fires Install correctly in the centre of the ceiling if possible Test weekly 5 WAY PLUG ENGAGES SOCKET ON MOUNTING PLATE TO CONNECT BATTERIES HARD WIRING INTER...

Page 3: ...pread of fire but unfortunately they can also greatly slow down the response time of alarms as they block the smoke getting to them Without interconnection closed doors also greatly reduce the alarm sound level throughout the house so even though the fire is detected early the alarm may not be heard The Ei405 Radio Smoke Alarms offer the comfort of intercon nection without the hassle of installing...

Page 4: ... should be located between the sleep ing area and the most likely sources of fire living room or kitchen for example But it should not be more than 10 paces 7 5 metres from the door to any room where a fire might start and block your escape from the house 3 1 Single Storey Dwelling If your Home is on one level a bungalow or mobile home for example you should put your first Smoke Alarm in a corrido...

Page 5: ...ea for example see figure 3 3 2 Multi Storey Dwellings If your home has more than one floor at least one alarm should be fitted on each level see figure 4 The Ei405 Radio smoke alarms are ideal in this situation as they are automati cally interconnected without wiring Figure 4 Multi Storey Dwelling BEDROOM DINING ROOM KITCHEN BEDROOM BEDROOM BEDROOM DINING ROOM KITCHEN BEDROOM BATH ROOM BEDROOM LI...

Page 6: ...of your Hi Fi System The Hi Fi system should be set to a reasonably loud conversation level If you can t hear it over your radio the chances are that it wouldn t wake you These Wireless interconnect smoke alarms will help to ensure the alarm will be heard through out the house 4 POSITIONING YOUR SMOKE ALARM 4 1 Hot smoke rises and spreads out so a central ceiling position is the recommended locati...

Page 7: ... directly above heaters or air conditioning vents windows wall vents etc that can change the direction of airflow In very high or awkward areas where it may be difficult to reach the alarm for testing Locate unit at least 1 5m away from fluorescent light fit tings as electricial noise and or flickering may affect the unit Locate away from very dusty or dirty areas as dust build up in the chamber c...

Page 8: ...l exactly where you want to mount the unit With a pencil mark the location of the two screw holes 4 Taking care to avoid any electrical wiring in the ceiling drill holes through the centres of the marked locations Push the plastic screw anchors provided into the drilled holes Screw in firmly 5 Connect the battery to the battery snaps as shown in figure 1b models Ei405 Ei405C only 6 Carefully line ...

Page 9: ...tton The local alarm will cease and you should then be able to hear the other alarms sounding in the dis tance 3 Repeat this procedure for all the other alarms If any units appear not to operate remove models Ei405 Ei405C only from the mounting plate as shown in figure 1a and ensure battery is firmly connected to the snaps If the wireless link does not appear to operate ensure you have held the te...

Page 10: ...e used it must also be put into the program mode at this time by holding the Test and Locate button down simultaneously see RF Remote Control section below On each smoke alarm the blue light will flash rapidly to show the number of units with which it has communicated The units will stay in program mode for 15 minutes and then reset automatically A smoke alarm can be taken out of pro gram mode qui...

Page 11: ...his indicates that the chamber has been tested in exactly the same way as if the test button on the unit itself had been pressed Hush If a unit is giving a nuisance alarm e g from cooking fumes pressing the Hush button on the remote control within range of the alarm will silence it for 10 minutes Note only units sensing smoke i e with their red light flashing rapidly will have their smoke sensitiv...

Page 12: ...has been silenced It can also be silenced using the Hush Button on the optional remote control Ei 410 provided it is sensing smoke itself 2 The unit will reset to normal sensitivity at the end of the silenced period If additional silenced time is required simply push the test button again 3 If the cause of the alarm is not clear it should be assumed that it is due to an actual fire and the dwellin...

Page 13: ...ensing chamber causing the alarm to sound If this happens the alarm must be returned to us for servicing or replacement Contamination is beyond our control it is totally unpredictable and is consid ered normal wear and tear For this reason contamination is not covered by the guarantee and a charge is made for all servicing work If you experience persistent false alarms in particular loca tions due...

Page 14: ...he battery Do not put the Smoke Alarm into a fire 7 HARDWIRE INTERCONNECTION Models Ei 405C Ei 405TYC only Sometimes it may be required to interconnect to battery pow ered Ei Electronics Smoke Alarms which do not have wireless interconnect If any of the interconnected units detect smoke the Ei 405C Ei 405TYC model will send a Radio alarm signal A maximum of twelve Ei 405C Ei 405TYC Ei 3105TYC Ei 1...

Page 15: ... attach the smoke alarm to the mounting plate After wiring together the Interconnect Smoke Alarms test the first unit by pressing the button All the detectors should alarm and the test button on the first unit will flash about once a second Please note it can take up to 5 seconds for some of the interconnected units to sound Check all the other units similarly Check the Radio Interconnect as descr...

Page 16: ...stitute for insurance The sup plier or manufacturer is not your insurer 8 2 Limitations of Smoke Alarms Smoke Alarms have significantly helped to reduce the number of fire fatalities in countries where they are widely installed However independent authorities have stated that they may be ineffective in some circumstances There are a number of reasons for this Smoke Alarms will not work if the batt...

Page 17: ...from each room in the house Children tend to hide when they don t know what to do Teach children how to escape open windows and use roll up fire ladders and stools without adult help Make sure they know what to do if the alarm goes off 9 PLANNING YOUR ESCAPE ROUTE FOR WHEN THE ALARM GOES OFF 1 Check room doors for heat or smoke Do not open a hot door Use an alternate escape route Close doors behin...

Page 18: ...ay not protect against the three most common causes of fatal fires 1 Smoking in bed 2 Leaving children at home alone 3 Cleaning with flammable liquids such as petrol Further information can be obtained from the Fire Brigade 10 WHAT IS THE BEST SMOKE ALARM OPTICAL OR IONISATION Both types respond in all standard fires but each type may respond faster to particular fires as shown Ei Electronics manu...

Page 19: ...FIVE YEAR GUARANTEE Limited Ei Electronics guarantees this product against any defects that are due to faulty material or workmanship for a five year period after the original date of consumer purchase or receipt as a gift This guarantee only applies to normal conditions of use and service and does not include damage resulting from accident neglect misuse unauthorised dismantling or conta mination...

Page 20: ...h the requirements of the RTTE Directive Compatibility 1999 5 EC RF Performance to EN300220 3 EMC to EMC 301489 3 Approvals Complies with BS5446 1 2000 Test Hush Button Checks smoke sensor electronics and horn Also silences nuisance alarms for 10 minutes and then resets Humidity Range 15 to 95 RH non condensing Audible Alarm 85dB at 3m minimum Chamber Fault The unit checks the sensing chamber ever...

Page 21: ...smoke RF VISUAL INDICATOR BLUE Test Button Blue light indicates test button pressed On Transmission Blue LED lights continuously for 1 5 to 3 5 seconds while messages are being transmitted Low Battery Indication Unit beeps and red light flashes every 40 seconds On Ten Year battery units Ei405TY blue LED also flashes every 9 seconds if radio battery is low Size of System A maximum number of 32 unit...

Page 22: ...odes The serial numbers memorised can be deleted i e the smoke alarms can be uncoded by powering down the unit and disconnecting the battery Wait 10 sec onds Then hold down the test button while connecting the battery Hard Wired Interconnect Up to 11 Ei105C Ei103C or Ei3105TYCH can be connected with 2 core cable to an Ei405C or Ei405TYC RF Alarm signal will be transmitted if any unit senses smoke ...

Page 23: ...23 ...

Page 24: ...24 ...

Reviews: