Ei Electronics Ei 3105TY Instructions Manual Download Page 2

2

1. READ THIS FIRST

A Smoke Alarm is an early warning device. Used correctly it
can give you and your family valuable extra time to escape.

Open the unit and slide the switch as indicated. This
will connect the battery permanently. Press the test
button and the horn should sound.

• When the battery is first connected the Alarm may sound

for 2-3 seconds and/or the red light may flash quickly for 10
seconds  - 

this is normal.

• A Smoke Alarm does not prevent fires.

• Install correctly, in the centre of the ceiling if possible.

• Test weekly.

• If the Alarm beeps 

without

the red light flashing at the

same time then clean unit as this is the automatic test
feature telling you the chamber is degraded.

• Plan your escape route.

• Proper protection may require more than one Smoke

Alarm.

• If you have any doubt or query about Smoke Alarms

consult the supplier or your local Fire Brigade.

• When the Alarm beeps 

and

the red light flashes at the

same time it indicates the battery is depleted and the entire
alarm must be replaced. This normally occurs when over
10 years has elapsed.

2. LOCATING YOUR SMOKE ALARM

Sufficient smoke must enter your Smoke Alarm before it will
respond. Your Smoke Alarm needs to be within 10 paces (7.5
metres) of the fire to respond quickly. It also needs to be in a
position where its alarm can be heard throughout your home,
so it can wake you and your family in time for you all to
escape. A 

single

Smoke Alarm will give some protection if it

is properly installed, but most homes will 

require

two or more

to ensure that a reliable early warning is given. For maximum
protection you should put individual Smoke Alarms in all the
rooms where fire is most likely to break out.
Your first Smoke Alarm should be located between the
sleeping area and the most likely sources of fire (living room
or kitchen for example). But it should not be more than 10
paces (7.5 metres) from the door to any room where a fire
might start and block your escape from the house.

B14355-R4-TY-UC-ENG-3105  21/12/10  1:30 PM  Page 2

Summary of Contents for Ei 3105TY

Page 1: ...with a plastic bag or similar before renovations begin Ei Electronics 2008 P N B14355 Rev4 10 YEAR SMOKE ALARM WITH 10 YEAR LITHIUM BATTERY BUILT IN INSTRUCTION LEAFLET Contains vital information on...

Page 2: ...ht flashes at the same time it indicates the battery is depleted and the entire alarm must be replaced This normally occurs when over 10 years has elapsed 2 LOCATING YOUR SMOKE ALARM Sufficient smoke...

Page 3: ...long one Smoke Alarm will not be sufficient This is because no matter where it is located it will be more than 7 5 metres from potential fires Recommended locations Figures 1 2 3 for minimum protecti...

Page 4: ...occur for instance where there is an electrical appliance such as an electric blanket or heater or where the occupant is a smoker You could also consider putting Smoke Alarms in any rooms where the o...

Page 5: ...d ceilings install your Smoke Alarm 0 9m from the highest point measured horizontally see figure 5 because dead air at the apex may prevent smoke from reaching the unit 3 4 Locations to Avoid Don t pl...

Page 6: ...should get your family into a safe place before you start investigating Check the house carefully in case there is a small fire smouldering somewhere Check whether there is some source of smoke or fu...

Page 7: ...ical wiring in the ceiling drill holes through the centres of the marked locations Push the plastic screw anchors provided into the drilled holes Screw in firmly 4 2 Connecting the built in Lithium Ba...

Page 8: ...to 10 seconds Figure 7 The alarm will stop sounding shortly after the button is released If the alarm fails to sound follow this checklist Check the age of the unit see replace by label on base of un...

Page 9: ...while cleaning Do not vacuum or brush inside the Smoke Alarm To clean the cover remove it completely and use only mild soap and water Dry cover thoroughly before replacing it WARNING Do not paint you...

Page 10: ...End of life The entire Smoke Alarm must be replaced if i The unit is installed for over 10 years check the replacement year marked on the unit ii The unit is giving a short beep every 40 seconds and...

Page 11: ...ential that all such openings including the wiring hole see figure 9 be closed by silicone sealant or similar After wiring together the Interconnect Smoke Alarms test the first unit by pressing the bu...

Page 12: ...larm see Getting your Smoke Alarm Serviced page 15 This appliance is intended ONLY for premises having a residential type environment This is not a portable product It must be mounted following the in...

Page 13: ...ton to familiarize your family with the Alarm sound and to practice fire drills regularly with all family members Draw up a floor plan that will show each member at least 2 escape routes from each roo...

Page 14: ...mouldering cigarettes and ashes Service central heating systems regularly Be sure all electrical appliances and tools have a recognised approval label This device cannot protect all persons at all tim...

Page 15: ...sed and the date of purchase FIVE YEAR GUARANTEE Limited Ei Electronics guarantees this product against any defects that are due to faulty material or workmanship for a five year period after the orig...

Page 16: ...nt or to human health When disposing of this product please separate it from other waste streams to ensure that it can be recycled in an environmentally sound manner For more details on collection and...

Reviews: