Fast CO Test Mode :Pressing the test button also causes the
unit to check for CO immediately. This facil-
itates testing with actual CO. If CO is
sensed it gives 3 beeps and the red light
flashes, about 4 seconds later. It then re-
sets.
Initialisation Time: 20 seconds. On power up red and amber
lights flash once
Operating Temperature
:-5
°
C to 40
°
C
Humidity Range
:15% to 95% R.H. (non-condensing)
Audible Alarm
:85dB(A) at 3m (10ft) minimum
Self Diagnostics
:Horn beep and amber fault light flashes
every 45 seconds if a fault is found.
Dimensions
: 135mm X 105mm X 71mm
Weight
: 290g
If your CO Alarm fails to work after you have carefully read all the
instructions, checked the unit has been installed correctly, and
is receiving AC power, return it for repair or replacement. This
should be to where it was purchased, or alternatively return it in
a padded box to “Customer Assistance and Information” at the
nearest address given on the CO Alarm or in this leaflet.
State
the nature of the fault
, where the CO Alarm was purchased,
and the date of purchase.
Ei Electronics guarantees this Carbon Monoxide Alarm for two
years from date of purchase against any defects that are due to
faulty materials or workmanship. This guarantee only applies to
normal conditions of use and service, and does not include
damage resulting from accident, neglect, misuse, unauthorised
dismantling, or contamination howsoever caused. This guaran-
tee excludes incidental and consequential damage. If this Car-
bon Monoxide Alarm should become defective within the
guarantee period, it must be returned to where it was purchased
or alternatively to Ei Electronics, carefully packaged, with the
problem clearly stated. (see section 9 “Getting the CO Alarm
Serviced”) along with proof of the date of purchase. We shall at
our discretion repair or replace the faulty unit.
Do not interfere with the carbon monoxide alarm or attempt to
tamper with it. This will invalidate the guarantee, but more im-
portantly may expose the user to shock or fire hazards.
This guarantee is in addition to your statutory rights as a con-
sumer.
ALARM DOES NOT WORK WITH THE TEST BUTTON:
(1) Check that the green mains power light is on. If it is off, check
the plug, fuse, circuit breakers and socket wiring etc.
(2) Hold the test button down for at least 5 seconds.
ALARM BEEPS EVERY 45 SECONDS:
(1) If the alarm beeps and the amber fault light flashes every 45
seconds, the CO sensor is possibly defective. Press the
test/hush button to reset the unit. If the beeping and the am-
ber light flashing re-occurs after 5 minutes, the unit is defec-
tive.
ALARM SOUNDS FOR NO APPARENT REASON:
Follow the detailed instructions in section 1. entitled
“What to
do when the alarm sounds”.
(1) Ensure there are no fuel burning appliances in the vicinity
which could be leaking CO gas (e.g. even from next door).
(2) Ensure there are no fumes in the area (e.g. paint, thinners,
hair spray, chemical cleaners, aerosol sprays etc).
(3) Ensure there is no outdoor source of CO in the vicinity (e.g. a
car with engine running, heavy traffic, heavy air pollution,
barbecue fumes etc).
(4) Press the test/hush button to silence the alarm.
If the unit continues to sound it is possibly defective and should
be replaced (see section 9 “Getting the CO Alarm Serviced”).
Ei Electronics
. Shannon, Co.Clare, Ireland.
Ei Electronics.
9 Grundy Street, Liverpool L5-9SG, U.K.
Tel: 0151-2981588
www.eielectronics.com
TROUBLE SHOOTING
11.
14
B14672
Two Year Guarantee
10.
Getting the CO Alarm Serviced
9.
15
16