![EHP TELEBOX PLC Technical Manua Download Page 31](http://html1.mh-extra.com/html/ehp/telebox-plc/telebox-plc_technical-manua_2368706031.webp)
Byte #:
ASCII:
Meaning:
A
Scale was switched off manually
X
Scale was switched off by the automatic switch-off
function
Q
TELEBOX manually switched off
E
Reception disturbance
C
TEST
13.
V
Scale battery charged
H
Prewarn /empty battery of the scale
L
Battery of the scale discharged
14.
(1-99)
Digit 1 of the scale no.
15.
(1-99)
Digit 2 of the scale no.
16.
(0)
Command block (not used)
17.
N
No overload
J
G
Overloaded
Preload too high (only for calibratable version)
18.
V
Battery of the TELEBOX charged ( only simulated)
19.
0
Password 1st character (not active)
20.
0
Password 2nd character (not active)
21.
03 H
Block end character (03 Hex)