![background image](http://html1.mh-extra.com/html/ego/power-zt4200l/html/ego/power-zt4200l/power-zt4200l_operators-manual_2368149066.webp)
56-VOLT LITHIUM-ION ELECTRIC ZERO TURN MOWER — ZT4200L/ZT4200L-FC
66
LCD
Display Description
Fault code
on LCD
LED
Status
Indicator
Beeper
Cause
Solution
see
“Fault
code”
Battery Box Assembly not func-
tioning.
217
n/a
one beep
The power
source from
Battery Box
assembly
is broken.
The LED
headlights
and USB wiil
not work.
Have repairs performed by a quali-
fied service technician.
310/410
OFF
one beep
The con-
nection be-
tween Type
C wires of
Battery Box
assem-
bly and
other Type C
wires of the
mower is
out of work.
Have repairs performed by a quali-
fied service technician.
201/202/203 OFF
one beep
The BMS
of the Bat-
tery Box
assembly is
broken.
Have repairs performed by a quali-
fied service technician.
see
“Fault
code”
Start/stop Switch Fault
314/414
OFF
one beep
Switch
PCBA failure
or bad wire
connection
for Start/
stop Switch.
Have repairs performed by a quali-
fied service technician.
see
“Fault
code”
LCD Screen Fault
315/415
OFF
one beep
LCD as-
sembly is
broken or
bad wire
connection
of the LCD
assembly.
Have repairs performed by a quali-
fied service technician.