CONNECTING COMMUNICATION CABLE
Turn off power and then connect the accessory cable between the COM port of PC and torque
wrench.
UPLOADING RECORD DATA
- Make sure the connection between PC and wrench is normal.
- Change the wrench operation mode to “Send”. (Please refer to “Peak Hold Mode Recorded
Value Review” section)
- Use PC to start the uploader program.
- In uploader program, first select the correct COM port No.
- Next, select the file path to save the uploaded data.
- Finally, press “upload” button to transmit the torque records to PC.
- The uploaded data is then shown on the column and saved in the *.csv file. Use Microsoft
Excel to view *.csv file.
CAUTIONS:
Refer to the uploader program user guide for the detail operations.