Ega Master 62981 Operating Instructions Manual Download Page 20

20

Step 4: PRE-TIGHTEN WRENCH

- Hold on your wrench to pre-tighten the screw. (eliminate the backlash of wrench)

Step 5: START TO MEASURE ANGLE

- Press to start the angle meter and immediately 

 pull your wrench.

Step 6: STOP AND WAIT FOR LCD FLASHING

- As the angle meter does not move for a few second, the LCD screen will be flashing and the 

current angle is holding on screen. It also means the meter stop calculating angle.

Note:

1. There are 6 LEDs to indicate the current angle reaching 80%, 85%, 90%, 95%, 97.5% and 

100% of target angle.

Summary of Contents for 62981

Page 1: ...MANUAL DE INSTRUCCIONES OPERATING INSTRUCTIONS ADAPTADOR ANGULAR ANGLE METER ESPA OL 2 ENGLISH 14 GARANTIA GUARANTEE 27 COD 62981...

Page 2: ...90 a una velocidad de 30 segundo Operaci n CW y CWW Timbre e indicador LED para 9 ngulos objetivo preestablecidos 50 o 250 datos de memoria para memoria y revisi n de ngulos Apagado autom tico al cab...

Page 3: ...60 C Temperatura de almacenamiento 20 C 70 C Humedad M s de 90 sin condensaci n Test de ca da 1 m Test medioambiental 5 Aprobado Test de compatibilidad electromagn tica 6 Aprobado Nota 1 Se garantiza...

Page 4: ...ensibilidad a radiaci n c Emisi n de radiaci n ANTES DE USAR EL ADAPTADOR INSTALACI N DE LAS PILAS Afloje los tornillos de la tapa de las pilas Inserte dos pilas AAA emparejando la polaridad de la pil...

Page 5: ...caci n aparece la opci n de apagado autom tico estar deshabilitada REINICIO Pulse el bot n para reinicio desde cero Normalmente pulse para reiniciar el adaptador angular digital antes de usar el adapt...

Page 6: ...debe sacudir el adaptador D jelo tranquilo Muestra que el adaptador no funciona correctamente por favor haga reinicio de hardware Vea el apartado REINICIO DE HARDWARE Si el adaptador oscila demasiado...

Page 7: ...por favor vea el apartado CAMBIO DE LA DIRECCI N DEL NGULO PASO 3 FIJE EL NGULO OBJETIVO Pulse para seleccionar el ngulo prefijado objetivo M1 M9 O pulse o para modificar el ngulo objetivo actual Teng...

Page 8: ...one la llave PASO 6 PARE Y ESPERE AL PARPADEO DEL LCD Cuando el medidor de ngulos no registre variaci n durante unos segundos la pantalla LCD comenzar a parpadear y el ngulo actual se fijar en la pant...

Page 9: ...IMINAR EL VALOR DEL NGULO RECALCULAR EL NGULO O GUARDAR LA MEDIDA DEL NGULO Pulsando se eliminar el ngulo actual Pulsando se recalcular de nuevo desde el ngulo actual Pulsando se grabara el valor actu...

Page 10: ...ulse o para seleccionar la direcci n Positivo significa en sentido de las agujas del reloj y negativo es en sentido antihorario Una vez fijada la direcci n pulse continuamente para salir del men de aj...

Page 11: ...la pantalla el mensaje Despu s de pulsar una vez se mostrar Si desea cancelar la operaci n pulse para salir de este men Pulsando repetidamente podr salir del men y volver a la pantalla de medici n del...

Page 12: ...idores que no admiten la fun ci n de comunicaci n CONEXI N DEL CABLE DE COMUNICACI N Apague el dispositivo y conecte el cable accesorio entre el medidor y el puerto COM del PC CARGA DE DATOS ALMACENAD...

Page 13: ...mpielo con un pa o seco lo antes posible La sal del agua marina puede ser especialmente da ina 5 No use disolventes org nicos tales como alcohol o acetonas para limpiar el medidor 6 Mantenga el medid...

Page 14: ...ut 2 rotating 90 at speed of 30 sec CW and CCW operation Buzzer and LED indicator for the 9 pre settable target angles 50 or 250 data memory for recall and angle auditing Auto power off after about 2...

Page 15: ...re 10 C 60 C Storage Temperature 20 C 70 C Humidity Up to 90 non condensing Drop Test 1 m Environmental test 5 Pass Electromagnetic compatibility test 6 Pass Note 1 The accuracy of the readout is guar...

Page 16: ...ctrostatic discharge immunity ESD b Radiation susceptibility c Radiation emission BEFORE USING THE METER BATTERY INSTALLATION Loosen the screw of the battery cap Insert two AAA batteries matching the...

Page 17: ...ution During communication period appears the auto power off function is disabled ZERO RESET Press for zero reset Usually press to zero reset the digital angle meter before using the meter It will gua...

Page 18: ...g process never vibrate or shake the meter Keep it rest shows that the meter does not work functionally please do hardware reset Refer to HARDWARE RESET If the meter rotates too fast will be shown Do...

Page 19: ...rent target angle will be shown Make sure the direction If you want to change to direction please refer to CHANGE ANGLE DIRECTION Step 3 SET TARGET ANGLE Press to select the pre set target angle M1 M9...

Page 20: ...ngle meter and immediately pull your wrench Step 6 STOP AND WAIT FOR LCD FLASHING As the angle meter does not move for a few second the LCD screen will be flashing and the current angle is holding on...

Page 21: ...s over 80 and long sound means it reaches over 100 of target angle Step 7 CLEAR ANGLE VALUE or CALCULATING ANGLE AGAIN or SAVE ANGLE RECORD Pressing will clear the current angle Pressing will calcualt...

Page 22: ...t the setup menu and go back to the current target angle screen CHANGE ANGLE DIRECTION Visit the direction menu press or to select the direction Positive means clockwise direction and negative is coun...

Page 23: ...ress or to select the data number you want to delete Press twice to delete the current data will be shown If press once will be shown If you want to abandon just press to skip out this menu Continuous...

Page 24: ...t does not support communication function CONNECTING COMMUNICATION CABLE Turn off power and then connect the accessory cable between the COM port of PC and meter UPLOADING RECORD DATA Make sure the co...

Page 25: ...as alcohol or paint thinner when cleaning the meter 6 Keep this meter away from magnets 7 Do not expose this meter to dust or sand as this could cause serious damage 8 Do not apply excessive force to...

Page 26: ...26...

Page 27: ......

Page 28: ......

Page 29: ......

Page 30: ......

Reviews: