Installation

   

The

 

unit

 

should

 

be

 

mounted

 

via

 

its

 

screw

 

holes

 

on

 

the

 

bracket.

 

Always

 

ensure

 

that

 

the

 

unit

 

is

 

firmly

 

fixed

 

to

 

avoid

 

vibration

 

and

 

slipping

 

while

 

operating.

 

Always

 

ensure

 

that

 

the

 

structure

 

to

 

which

 

you

 

are

 

attaching

 

the

 

unit

 

is

 

secure

 

and

 

is

 

able

 

to

 

support

 

a

 

weight

 

of

 

10

 

times

 

of

 

the

 

unit’s

 

weight.

 

Also

 

always

 

use

 

a

 

safety

 

cable

 

that

 

can

 

hold

 

12

 

times

 

of

 

the

 

weight

 

of

 

the

 

unit

 

when

 

installing

 

the

 

fixture.

   

The

 

equipment

 

must

 

be

 

fixed

 

by

 

professionals.

 

And

 

it

 

must

 

be

 

fixed

 

at

 

a

 

place

 

where

 

is

 

out

 

of

 

the

 

touch

 

of

 

people

 

and

 

has

 

no

 

one

 

pass

 

by

 

or

 

under

 

it.

 

 

4.

 

How

 

to

 

Set

 

the

 

Fixture

   

4.1

 

Control

 

Panel

   

 

 

1

Display:

 

To

 

show

 

the

 

various

 

menus

 

and

 

the

 

selected

 

functions

 

LED:

 

 

2 DMX

 

 

On

 

 

DMX

 

input

 

present

 

 

3 MASTER

 

 

On

 

 

Master

 

Mode

 

 

4 SLAVE

 

 

On

 

 

Slave

 

Mode

 

 

5 SOUND

 

 

Flashing

 

 

Sound

 

activation

 

Button:

 

6

 

MENU

 

 

To

 

select

 

the

 

programming

 

functions

 

Summary of Contents for ILED-7TC

Page 1: ...LED Panel 7TC ILED 7TC PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USE USER GUIDE...

Page 2: ...How to Set the Fixture 4 4 1 Control Panel 4 4 2Main Function 5 5 How to Control the Unit 10 A Universal DMX controller 10 B Master Slave operation 11 C Easy Controller by CA 8 11 6 DMX 512 Configura...

Page 3: ...stop using the fixture immediately Never try to repair the fixture by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical...

Page 4: ...ey are visibly damaged Caution There are no user serviceable parts inside the fixture Do not open the housing or attempt any repairs yourself In the unlikely situation your unit may require service pl...

Page 5: ...o always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture The equipment must be fixed by professionals And it must be fixed at a place where is out of th...

Page 6: ...o input DMX signal 14 Mains input Connect to supply mains power 15 Mains output Connect to supply mains power for the next unit 4 2Main Function To select any of the given functions press the MENU but...

Page 7: ...6B...

Page 8: ...n to the main functions without any change after 8 seconds To go back to the functions without any change press the MENU button again Show Mode Press the MENU button up to when the is shown on the dis...

Page 9: ...play Pressing ENTER button and the display will blink Use DOWN and UP button to select the sound control on or sound control off Once the mode has been selected press the ENTER button to setup or auto...

Page 10: ...NTER button to setup or automatically return to the main functions without any change after 8 seconds To go back to the functions without any change press the MENU button again Display Inversion It is...

Page 11: ...To go back to the functions press the MENU button again Software version Press the MENU button up to when the is blinking on the display Pressing ENTER button and the display will show the version of...

Page 12: ...t as a Master or as a Slave C Easy Controller by CA 8 The easy remote control is used only in master slave mode There is a terminator for connect the easy controller inside the fixture By connecting t...

Page 13: ...12B 6 DMX 512 Configuration 4 Channels Mode...

Page 14: ...and input connectors pass through to maintain the DMX circuit when one of the units power is disconnected 3 At last fixture the DMX cable has to be terminated with a terminator to reduce signal error...

Page 15: ...or on PCB of the fixture or the previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DM...

Page 16: ...e environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture s optics y Clean with soft cloth using normal glass clean...

Page 17: ...e with the provision of the Electromagnetic Compatibility EMC Directive 2004 108 EC EN55103 1 2009 EN55103 2 2009 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 Harmonized Standard EN 60598 1 2008...

Page 18: ...the right to change specifications without prior notification Images are representing but not necessarily a precise product reference EFX shall be under no liability for any loss damage or injury for...

Reviews: