PF321A6012
- 21 -
Display example of operating hours or hours since the last service and operating hours counter reset.
Display on the control:
Select parameter 177.
Press the
E
key
Sr7
Press the
>>
key
h t
(hours /thousands letter symbol)
Press the
E
key
000
hours /thousands display)
Press the
E
key
h h
(hours / hundreds letter symbol)
Press the
E
key
000
(hours / hundreds display)
Press the
E
key
Min
(minutes letter symbol)
Press the
E
key
00
(minutes display)
Press the
E
key
SEc
(seconds letter symbol)
Press the
E
key
00
(seconds display)
Press the
E
key
MS
(milliseconds letter symbol)
Press the
E
key
000
(milliseconds display)
Press the
E
key
rES
see chapter “Set and Reset Operating Hours Counter “
Press the
E
key
The process will be repeated from the hours display.
Press the
P
key twice
e. g.
400
(sewing process can be started)
Display on the V810 control panel:
Select parameter 177.
Press the
E
key
Sr7 [°]
Press the
>>
key
hoUr
(hours letter symbol)
Press the
E
key
000000
(hours display)
Press the
E
key
Min
(minutes letter symbol)
Press the
E
key
00
(minutes display)
Press the
E
key
SEc
(seconds letter symbol)
Press the
E
key
00
(seconds display)
Press the
E
key
MSEc
(milliseconds letter symbol)
Press the
E
key
000
(milliseconds display)
Press the
E
key
rES
F2
see chapter “Set and Reset Operating Hours Counter “
Press the
E
key
The process will be repeated from the hours display.
Press the
P
key twice
e. g.
PF321A
(sewing process can be started)
Display on the V820/V850 control panel:
Select parameter 177.
Press the
E
key
F-177
Sr7
[°]
Press the
>>
key
hoUr
000000
(hours display)
Press the
E
key
Min
00
(minutes display)
Press the
E
key
Sec
00
(seconds display)
Press the
E
key
MSEc
000
(milliseconds display)
Press the
E
key
rES
F2
see chapter “Set and Reset Operating
Hours Counter “
Press the
P
key twice
e. g.
3500
PF321A
(sewing process can be started)
6.16.1 Set and Reset Operating Hours Counter
The number of hours has been reached (service necessary):
Press the
>>
key or
F2
once
The operating hours counter is set to "0" and restarted.
The number of hours has not yet been reached:
Press the
>>
or
F2
key 3 times
The operating hours counter is set also to "0" and
restarted.
A value in parameter 177 has been changed:
After displaying
rES ...,
when the
E
key is pressed again,
SEt
will then be displayed.
If the changed value is to be saved, press the
>>
or
F2
key 3 times.
Summary of Contents for DC 1550
Page 51: ... PF321A6012 51 For your notes ...